41
2 Troubleshooting Procedures
NB200 Series Maintenance Manual
41
Procedure 2: Connector and replacement check
Procedure 1
Diagnostic test
Run the functioning Program on Windows model, which will display the MIC test result.
If tests and diagnostics result abnormal go to Procedure 2. If an error is not located, the MIC
module functioning is properly.
Procedure 2
Connector and replacement check
The MIC line or system board may be disconnected or damaged. Disassemble the computer
following the steps described in Chapter 4,
Replacement Procedures
, and perform the
following checks.
Check 1
Make sure that the MIC line is securely slotted into the system board. If the
problem remains, go to Check 2.
Check 2
The MIC line may be damaged. Replace it with a new one following the
instructions in Chapter 4. If the problem still exists, perform Check 3.
Check 3
The system board may be damaged. Replace it with a new one following the
instructions in Chapter 4.
2.16 3D Sensor Troubleshooting
Содержание mini NB250 series
Страница 1: ...Toshiba Personal Computer NB250 NB255 Maintenance Manual TOSHIBA CORPORATION ...
Страница 12: ...Chapter 1 Hardware Overview ...
Страница 15: ......
Страница 28: ...Chapter 2 Troubleshooting Procedures 2 ...
Страница 29: ......
Страница 64: ...352 Troubleshooting Procedures NB200 Series Maintenance Manual 35 ...
Страница 75: ...3 Tests and Diagnostics 1 Chapter 3 Tests and Diagnostics ...
Страница 87: ...3 Tests and Diagnostics 13 ...
Страница 90: ...3 Tests and Diagnostics Japan keyboard UK keyboard 16 ...
Страница 94: ...3 Tests and Diagnostics 2 If the Magnetic switch test pass it will show below display 20 ...
Страница 97: ...3 Tests and Diagnostics If an error is detected and a test fails the following message displays 23 ...
Страница 101: ...3 Tests and Diagnostics If the picture shows as below it means the 3D G sensor function is NG 27 ...
Страница 111: ...3 Tests and Diagnostics If an error is detected and a test fails the following message displays 37 ...
Страница 114: ...3 Tests and Diagnostics If W R T P type passes the screen would display as below 40 ...
Страница 117: ...3 Tests and Diagnostics If press 7 to disable all no support function program will perform automatically as below 43 ...
Страница 118: ...3 Tests and Diagnostics 44 ...
Страница 120: ...3 Tests and Diagnostics 46 ...
Страница 121: ...Chapter 4 Replacement Procedures ...
Страница 126: ......
Страница 203: ...3 Thai TI Keyboard Figure TI keyboard 4 Korean KO Keyboard Figure KO keyboard NB250 NB255 Series Maintenance Manual ...
Страница 204: ...5 United Kingdom UK Keyboard Figure UK keyboard 6 US International UI Keyboard NB250 NB255 Series Maintenance Manual ...
Страница 205: ...Figure UI keyboard 7 Hebrew HB Keyboard Figure HB keyboard 8 Danish DM Keyboard NB250 NB255 Series Maintenance Manual ...
Страница 206: ...Figure DM keyboard 9 Swiss SW Keyboard Figure SW keyboard NB250 NB255 Series Maintenance Manual ...
Страница 210: ...NB250 NB255 Series Maintenance Manual 16 French FR Keyboard Figure FR keyboard 17 German GR Keyboard Figure GR keyboard ...
Страница 211: ...NB250 NB255 Series Maintenance Manual 18 Greek GK Keyboard Figure GK keyboard 19 Hungarian HG Keyboard ...
Страница 213: ...Figure TR keyboard 22 Turkish F TF F Keyboard Figure TF F keyboard NB250 NB255 Series Maintenance Manual ...
Страница 219: ...Figure JP keyboard NB250 NB255 Series Maintenance Manual ...