3.21 Running Test
3 Tests and Diagnostics
3-44
Libretto 50CT/70CT Maintenance Manual
3.21 Running Test
3.21.1 Function Description
This function automatically executes the following tests in sequence:
1
System test (subtest number 01)
2
Memory test (subtest number 01, 02, 04, 06)
3
Display test (subtest number 01 to 08)
4
FDD test (subtest number 02)
5
HDD test (subtest number 01, 05)
6
Real timer test (subtest number 02)
7
Printer test (subtest number 03) if selected
8
Async test (subtest number 01) if selected
The system automatically detects the number of floppy disk drives connected to the
computer for the FDD test.
3.21.2 Operations
NOTE
: Do not forget to load a work disk in the FDD. If a work disk is not loaded, an
error will be generated during the FDD test.
1.
Remove the diagnostics disk from the floppy disk drive and insert the work disk.
2.
Select
6
from the Diagnostic Menu and press
Enter,
the following message displays:
Printer wrap around test (Y/N) ?
Select
Y (yes)
to execute the printer wraparound test. A printer wraparound
connector must be connected to the parallel port of the computer to properly execute
this test.
3.
Select
Y
or
N
and press
Enter
. The following message displays:
Serial #A wrap around test (Y/N) ?
Select
Y (yes)
to execute the ASYNC wraparound test. An RS-232C wraparound
connector must be connected to the serial port of the computer to properly execute
this test.
4.
Select
Yes
or
No
and press
Enter
. The following message displays:
Mount the work disk(s) on the drive(s),
then press [Enter] key.
[Warning : The contents of the disk(s),
will be destroyed.]
5.
This program is executed continuously. To terminate the program, press
Ctrl +
Break.
Содержание Libretto 50CT
Страница 8: ...viii Libretto 50CT 70CT Maintenance Manual ...
Страница 10: ...Chapter 1 Hardware Overview ...
Страница 11: ...1 ii Libretto 50CT 70CT Maintenance Manual ...
Страница 30: ...Chapter 2 Troubleshooting Procedures ...
Страница 31: ...2 ii Libretto 50CT 70CT Maintenance Manual ...
Страница 61: ...Chapter 3 Tests and Diagnostics ...
Страница 62: ...3 ii Libretto 50CT 70CT Maintenance Manual ...
Страница 64: ...3 iv Libretto 50CT 70CT Maintenance Manual 3 22 2 Operations 3 45 ...
Страница 128: ...Chapter 4 Replacement Procedures ...
Страница 129: ...4 ii Libretto 50CT 70CT Maintenance Manual ...
Страница 167: ...Appendices ...
Страница 168: ...App ii Libretto 50CT 70CT Maintenance Manual ...
Страница 178: ...Appendix B Board Layout B 4 Libretto 50CT 70CT Maintenance Manual ...
Страница 183: ...Appendix C Pin Assignments Libretto 50CT 70CT Maintenance Manual C 5 ...
Страница 186: ...Appendix Appendix C Pin Assignments C 8 Libretto 50CT 70CT Maintenance Manual 43 GND 44 NC ...
Страница 194: ...Appendix F BIOS Rewrite Procedures F 2 Libretto 50CT 70CT Maintenance Manual ...
Страница 196: ...Appendix G Reliability G 2 Libretto 50CT 70CT Maintenance Manual ...