− 42 −
6F8A0926
9.2
Type Specification Code
Table 9.3 Type Specification Code
Model Specification
Code
Detector category
1 2 3 4 5 6 7
8 9 10
11
12
13 14
Description
Gr.-A Gr.-B
L F 6 5
Flange type electromagnetic flowmeter detector
4
Usage
cFMus Division 2 Hazardous Location
√
√
Meter
size
D
½"(15mm)
√
E
1"(25mm)
√
S
1¼"(32mm)
√
F
1½"(40mm)
√
G
2"(50mm)
√
W
2½"(65mm)
√
H
3"(80mm)
√
J
4"(100mm)
√
U
5”(125mm)
√
K
6"(150mm)
√
L
8"(200mm)
√
M
10"(250mm)
√
N
12"(300mm)
√
P
14"(350mm)
√
Q
16"(400mm)
√
R
18"(450mm)
√
Mounting
Style
L
Detector/Converter
combined
type
√
√
M
Detector/Converter
separate
type
√
1
Detector/Converter separate type (Note 1)
√
Connection flange standard, Overall length
C
ANSI
150,
ISO
length
{
{
D
ANSI
300,
ISO
length
{
{
1
ANSI 150, Toshiba length
z
z
2
ANSI 300, Toshiba length
{
{
Electrode Material (Note 2)
B
316L stainless steel (Standard for Polyurethane lining)
z
z
C
Ti
(titanium)
{
{
D
Pt-Ir
(platinum/iridium)
{
{
E
Ta
(tantalum)
{
{
F
Hastelloy C (Equivalent) (Standard for PFA lining)
z
z
Lining Materials (Note 2)
C
PFA (Standard for Hastelloy C electrode)
z
z
N
Polyurethane (NSF certified)
(Standard for 316L electrode) (Note 6)
z
z
Grounding Ring Material (Note 2)
C
316
stainless
steel
z
z
D
316L
stainless
steel
{
{
E
Ti
(titanium)
{
{
F
Ta
(tantalum)
{
–
G
Pt-Ir
(platinum/iridium)
{
–
H
Hastelloy
C
(Equivalent)
{
{
Flow and calibration velocity range
A
1.0 to 32.8 ft/s (standard range calibration)
z
z
B
1.0 to 32.8 ft/s (specified range calibration)
{
{
C
0.3 to 32.8 ft/s (specified range calibration)
{
{
Excitation
and
Signal
Cables
A
not
provided
z
z
B
30m cable, provided (Note 3)
{
{
C
other lengths, provided (Note 4)
{
{
Coating
F
PU
coating
pearl-gray
colored
z
z
C
black tar epoxy resin 0.3mm
{
{
D
black tar epoxy resin 0.5mm
{
{
E
black tar epoxy resin 0.5mm for submersible type
(Note 5)
{
{
Size code explanation:
√
: Object
z
: Standard
{
: Option –: Not available
Note1:
Range of ambient temperature is from -4
°F
to 140
°F (-20 to +60C)
.
Note2
: Consult Toshiba before ordering when choose materials at the wetting parts.
Note3
: Separate type detector only.
Note4
: Separate type detector only. Specifying the code “C”, indicate the length of cables from 1 to 300m 1 meter increments.
Note5
: Polyurethane lining is available to choose only in this specification.
Note6
: Electrode is available for 316L stainless steel only and Grounding ring is available for 316/316L stainless steel only.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]