Toshiba LF610 Series Скачать руководство пользователя страница 2

Size 

(mm)

Flow rate

0.3m/s

1m/s

3m/s

10m/s

2.5

0.005301 

0.01767 

0.05304 

0.1767 

4

0.01357 

0.04524 

0.13572 

0.4524 

6

0.03053 

0.1018 

0.3054 

1.018 

15

0.1908 

0.6361 

1.908 

6.361 

25

0.5301 

1.767 

5.301 

17.67 

32

0.8686 

2.895 

8.686 

28.95 

40

1.357 

4.523 

13.57 

45.23 

50

2.120 

7.067 

21.20 

70.67 

65

3.583 

11.95 

35.83 

119.5 

80

5.428 

18.09 

54.28 

180.9 

100

8.482 

28.27 

84.82 

282.7 

125

13.25 

44.17 

132.5 

441.7 

150

19.08 

63.61 

190.8 

636.1 

200

33.93 

113.1 

229.3 

1,131 

250

53.01 

176.7 

530.1 

1,767 

300

76.34 

254.5 

763.4 

2,545 

350

103.9 

346.4 

1,039 

3,464 

400

135.7 

452.3 

1,357 

4,523 

450

171.7 

572.5 

1,717 

5,725 

500

212.1 

706.9 

2,121 

7,069 

600

305.4 

1,018 

3,054 

10,180 

700

415.6 

1,385 

4,156 

13,850 

750

477.1 

1,590 

4,771 

15,900 

800

542.9 

1,810 

5,429 

18,100 

900

687.1 

2,290 

6,871 

22,900 

Factory default standard value table

Code

Item

Default value

Changed value

English unit

SI unit

A3

Exicitation Frequency

Value

Value 

A4

Flow Direction

NORMAL

NORMAL

B1

Display 1

gal/min

m

3

/h

B2

Display 2

COUNT B

m

3

Display digit setting 

(For Display 1 and Display 2)

1/1000

1/1000

B3

Custom Coefficient

0

0

B4

Custom Unit

Blank space in all field Blank space in all field

C1

Range Type

SINGLE

SINGLE

C2

Range 1 

Value

Value 

C6

Hysteresis

3.0%

3.0%

D1

Damping Constant

5 sec

1 sec

D2

Rate-of-change Limit

0.0%

0.0%

D3

Control Limit Time

0.0s

0.0s

E1

Low Cutoff

1.0%

1.0%

E2

Display Low Cutoff 

LINEAR

LINEAR

F2

Manual Zero

0.0%

0.0%

G1

4-20mADC Alarm Output

4mA

4mA

G2

Output Low Limit

4mA

4mA

H1

DO1 Function

PLS OUT

PLS OUT

H2

DO2 Function (*)

EMPTY ALM

NO USE

H3

DO1 Active Status

NormOPEN

NormOPEN

H4

DO2 Active Status (*)

NormOPEN

NormOPEN

I1

Digital input (*)

C RS/ST

C RS/ST

I2

DI Detective Level (*)

H LEVEL

H LEVEL

J1

Counting Rate

Value

Value 

J2

Pulse width setting mode

AUTO

AUTO

J3

Preset width

5ms

100ms

K1

Preset count

00000000

00000000

K2

Preset Function

HOLD

HOLD

L1,L2 High Alarm Set / Value

OFF 0.0%

OFF 0.0%

L3,L4 Low Alarm Set / Value

OFF 0.0%

OFF 0.0%

M1,M2 High High Alarm Set / Value

OFF 0.0%

OFF 0.0%

M3,M4 Low Low Alarm Set / Value

OFF 0.0%

OFF 0.0%

N1

Empty Pipe Alarm

NORMAL

NORMAL

N2

Self-disgnosis function

ON

ON

N3

Alarm Output Preset

CONV ONLY

CONV ONLY

P1

Password

000

000

P2

LCD display adjustment

3

3

P3

Switch position setting

BOTTOM

BOTTOM

*  These functions are option.

 

Meter Size 

Ex.Freq

(Hz)

Range 1

Counting Rate

inch mm

gal/min

ft/s

m

3

/h

m/s

1/10''

24

0.5 21.084 

0.05

2.829  1 gal

1L

1/6''

24

1.5 24.707 

0.1

2.211  1 gal

1L

1/4''

24

4 29.283 

0.2

1.965  1 gal

1L

1/2''

15

24

25 29.283 

2

3.144  1 gal

0.01m

3

1''

25 

24

75 31.625 

6

3.395  1 gal

0.01m

3

1 1/4''

32 

24

125 32.171 

10

3.454  1 gal

0.01m

3

1 1/2''

40 

24

175 28.826 

15

3.316  1 gal

0.01m

3

2''

50 

24

300 31.625 

25

3.537  10 gal

0.1m

3

2 1/2''

65 

24

475 29.629 

40

3.348  10 gal

0.1m

3

3''

80 

24

650 26.766 

60

3.316  10 gal

0.1m

3

4''

100 

24

1,000 26.354 

100

3.537  10 gal

0.1m

3

5''

125 

24

1,750 31.625 

150

3.395  10 gal

0.1m

3

6''

150 

24

2,500 29.283 

200

3.144  100 gal

1m

3

8''

200 

24

4,500 29.649 

300

2.653  100 gal

1m

3

10''

250 

12

7,000 29.517 

600

3.395  100 gal

1m

3

12''

300 

12

10,000 28.283 

900

3.537  100 gal

1m

3

14''

350 

12

12,000 25.817 

1,200

3.465  100 gal

1m

3

16''

400 

12

16,000 26.354 

1,600

3.537  100 gal

1m

3

18''

450 

12

20,000 26.029 

2,500

4.366  100 gal

1m

3

20''

500 

6

25,000 26.354 

3,000

4.244  100 gal

1m

3

24''

600 

6

40,000 29.283 

4,000

3.930  100 gal

1m

3

28''

700 

6

50,000 26.892 

5,000

3.609  100 gal

1m

3

30''

750 

6

60,000 28.112 

6,000

3.773  100 gal

1m

3

32''

800 

6

70,000 28.825 

7,000

3.868  100 gal

1m

3

36''

900 

6

80,000 26.029 

8,000

3.930  100 gal

1m

3

ERROR/ALARM

Error/Alarm type

Indicating message

Error contents

Self-diagnosis error

ROM ERROR

ROM error

RAM ERROR

RAM error

PARAMETER FAILURE

System parameter error

EXC CUR OPEN

Excitation circuit error

EXC CUR ERROR

Excitation current error

ADC ERROR

ADC error

INVALID TOTAL

Invaid totalizer counts

Settig error

HIGH OVER SPEC

Setting value exceeds the allowable high limit.

LOW OVER SPEC

Setting value exceeds the allowable low limit.

HIGH OVER CNT RATE

Counting rate exceeds the allowable high limit.

LOW OVER CNT RATE

Counting rate exceeds the allowable low limit.

MULTI RNG ERROR

Span is not appropriate for multi-range configuration.

Limit alarms

HIGH ALARM

Flow rate reading exceeds the high limit.

HIGH HIGH ALARM

Flow rate reading exceeds the high high limit.

LOW ALARM

Flow rate reading goes below the low limit.

LOW LOW ALARM

Flow rate reading goes below the low low limit.

OVER 125%

Measurement value exceeds the 125%

UNDER -125%

Measurement value goes below the 125%

Empty pipe alarm

EMPTY ALARM

Detector pipe is not filled with fluid.

LCD

Meter Size vs. Velocity/Rate

Size 

(inch)

Flow rate

0.98ft/s

3ft/s

10ft/s

32.8ft/s

1/10''

0.02334 

0.07115 

0.2372 

0.7781 

1/6''

0.05975 

0.1821 

0.6071 

1.992 

1/4''

0.1344 

0.4098 

1.366 

4.482 

1/2''

0.8403 

2.561 

8.532 

28.01 

1''

2.334 

7.115 

23.72 

77.81 

1 1/4''

3.824 

11.66 

38.86 

127.5 

1 1/2''

5.975 

18.21 

60.71 

199.2 

2''

9.337 

28.46 

94.86 

311.2 

2 1/2''

15.78 

48.09 

160.3 

526.0 

3''

23.90 

72.85 

242.8 

796.7 

4''

37.35 

113.8 

379.4 

1,245 

5''

58.35 

177.9 

592.9 

1,945 

6''

84.03 

256.1 

853.8 

2,801 

8''

149.4 

455.3 

1,518 

4,980 

10''

233.4 

711.5 

2,372 

7,781 

12''

336.1 

1,025 

3,415 

11,200 

14''

457.5 

1,394 

4,648 

15,250 

16''

597.5 

1,821 

6,071 

19,920 

18''

756.3 

2,305 

7,684 

25,210 

20''

933.7 

2,846 

9,486 

31,120 

24''

1,344 

4,098 

13,660 

44,820 

28''

1,830 

5,578 

18,590 

61,000 

30''

2,101 

6,403 

21,340 

70,020 

32''

2,390 

7,285 

24,280 

79,670 

36''

3,025 

9,221 

30,740 

100,800 

unit : gal/min