24
In case of rainstorm
WARNING
■
If water penetrates into the escalator due to heavy rain etc., please
stop the escalator immediately (refer to page
16
for how to stop).
Continues the operation may lead to undesirable accident, if the equipment/parts
have been soak in water, replacement may be required.
■
When you suspend the escalator services, put up barricades to
prevent people from climbing up or down escalators like staircases
to prevent undesirable accident.
Otherwise, a trip or fall accident may occur.
In case of rainstorm (Possibility of water leakage)
Stop the escalator (Refer to page
16
for how to stop).
• When there is possibility of water leakage, please stop the escalator.
Create a dyke to prevent water from
flowing into the escalator.
[ After the rainstorm ]
Check the landing plate to ensure there is no trace of water
penetrated into the escalator.
• If any of water trace is detected, please stop the operation and contact the maintenance
service company (refer to page
16
for how to stop).
• If there is no trace of water leakage, please resume the operation (refer to page
15
for
how to start).
• Although the outdoor escalators are designed to withstand certain extend of rainstorm, but
we would recommend you to stop it in advance, like a normal escalator during rainstorm.
[ lf any parts of the escalator had been soaked in water during operation ]
Please stop the operation immediately and contact the maintenance
service company.
• Please do not resume operation under any circumstances unless procedures such as
the insulating measurement test etc. draining, dryness check have been done by an
authorized technician.
Safety measures in case of disaster