HX7+ ASD Installation and Operation Manual
121
Jog Run Frequency
Program
Frequency Setting
Jog Settings
This parameter sets the output frequency of the drive during a
Jog
.
Jogging
is
the term used to describe turning the motor on for small increments of time and
is used when precise positioning of motor-driven equipment is required.
Enabling the
Jog Window
allows for the
Manual Jog
window to be among the
screens accessed during repeated
MON/PRG
entries. This screen must be
displayed when
Jogging
using the keypad.
The
Jog
function may be initiated from the keypad or remotely via the
Terminal Board
or
using
Communications
(for further information on using
Communications
for
Jogging
, see the
Communications
manual).
To perform a
Jog
, set this parameter (
) to the desired
Jog
frequency.
Select a
Jog Stop
method (
).
Jog Setup Using the Keypad
To initiate a
Jog
from the keypad perform the following:
1. Place a check in the
Enable Jog Window
box (Program
Frequency
Setting
Jog Settings
Enable Jog Window
).
Note:
The
Jog Window
must be displayed on the keypad to perform the
Jog
function using the keypad.
2.Press
MON/PRG
to access the
Jog Window
.
3.Using the
Up/Down
arrow keys of the keypad, select
Reverse
or
Forward
.
4.Place the system in the
Local
mode (
Local|Remote
LED is on).
5.Press and hold the
Run
key for the desired
Jog
duration.
Jog Setup Using the Terminal Board
To initiate a
Jog
from the
Terminal Board
perform the following:
1. Assign a discrete input terminal to the
Jog
).
2.Assign a discrete input terminal to the
F
(
Forward
) function (and
Reverse
).
3.Provide a
Forward
and/or
Reverse
command from the
Terminal Board
.
4.From the
Jog Window
, use the
Up/Down
arrow keys of the keypad to
select
Reverse
or
Forward
(Program
Frequency Setting
Jog
Settings
Enable Jog Window
). Press
MON/PRG
to access the
Jog
Window
.
5.Place the system in the
Remote
mode (
Local|Remote
LED is off).
6.Connect the assigned
Jog
terminal (from step
) to
CC
for the desired
Jog
duration.
Direct Access Number — F260
Parameter Type —
Numerical
Factory Default —
0.00
Changeable During Run —
Yes
Minimum — 0.00
Maximum — 20.00
Units — Hz
Содержание HX7+ ASD
Страница 1: ...HX7 ASD Install Op Manual TOSHIBA HX7 ASD INSTALLATION OPERATION MANUAL DN 67017 001 February 2014 ...
Страница 2: ...DN 67017 001 February 2014 HX7 ASD Installation Operation Manual ...
Страница 219: ...210 HX7 ASD Installation and Operation Manual Figure 27 66 200 kVA Non Sine Wave NEMA 1 Enclosure ...
Страница 220: ...HX7 ASD Installation and Operation Manual 211 Figure 28 260 518 kVA Non Sine Wave NEMA 1 Enclosure ...
Страница 221: ...212 HX7 ASD Installation and Operation Manual Figure 29 518 1000 kVA Non Sine Wave NEMA 1 Enclosure ...
Страница 222: ...HX7 ASD Installation and Operation Manual 213 Figure 30 1200 1500 kVA Non Sine Wave NEMA 1 Enclosure ...
Страница 223: ...214 HX7 ASD Installation and Operation Manual Figure 31 66 200 kVA Non Sine Wave NEMA 3R Enclosure ...
Страница 224: ...HX7 ASD Installation and Operation Manual 215 Figure 32 260 518 kVA Non Sine Wave NEMA 3R Enclosure ...
Страница 225: ...216 HX7 ASD Installation and Operation Manual Figure 33 518 1000 kVA Non Sine Wave NEMA 3R Enclosure ...
Страница 226: ...HX7 ASD Installation and Operation Manual 217 Figure 34 1200 1500 kVA Non Sine Wave NEMA 3R Enclosure ...
Страница 227: ...218 HX7 ASD Installation and Operation Manual Figure 35 200 kVA Sine Wave NEMA 1 Enclosure ...
Страница 228: ...HX7 ASD Installation and Operation Manual 219 Figure 36 260 518 kVA Sine Wave NEMA 1 Enclosure ...
Страница 229: ...220 HX7 ASD Installation and Operation Manual Figure 37 518 1000 kVA Non Sine Wave NEMA 1 Enclosure ...
Страница 230: ...HX7 ASD Installation and Operation Manual 221 Figure 38 932 1500 kVA Sine Wave NEMA 1 Enclosure ...
Страница 231: ...222 HX7 ASD Installation and Operation Manual Figure 39 200 kVA Sine Wave NEMA 3R Enclosure ...
Страница 232: ...HX7 ASD Installation and Operation Manual 223 Figure 40 260 518 kVA Sine Wave NEMA 3R Enclosure ...
Страница 233: ...224 HX7 ASD Installation and Operation Manual Figure 41 518 1000 kVA Sine Wave NEMA 3R Enclosure ...
Страница 234: ...HX7 ASD Installation and Operation Manual 225 Figure 42 932 1500 kVA Sine Wave NEMA 3R Enclosure ...
Страница 235: ...226 HX7 ASD Installation and Operation Manual Figure 43 66 163 kVA 18 Pulse Enclosure ...
Страница 236: ...HX7 ASD Installation and Operation Manual 227 Figure 44 200 kVA 18 Pulse Enclosure ...
Страница 237: ...228 HX7 ASD Installation and Operation Manual Figure 45 260 518 kVA 18 Pulse Enclosure ...
Страница 238: ...HX7 ASD Installation and Operation Manual 229 Figure 46 518 700 kVA 18 Pulse Enclosure ...