– 9 –

Hydro Unit

Owner’s Manual

Useful functions

Frost protection

This function performs operation with the minimum 
capacity to prevent pipes from freezing in case the unit 
is not used for a long period due to absence.
• When the FROST PROTECTION  

button 

is 

pressed during heating (ZONE1 or ZONE2), 

 

appears on the remote controller and the 
temperature indication changes to “F“. The frost 
protection operation starts with the set minimum 
capacity (target water temperature: 15 °C).

• The frost protection mode can be stopped by either 

setting the end day and time using function codes or 
by pressing the FROST PROTECTION 

 button 

again on the remote controller.

• This function takes precedence over the Night 

setback quiet operation that is set separately. Ask 
the installation company for the minimum capacity 
setting.

• Cancel schedule timer to start frost protection 

operation. When frost protection is operated with 
schedule timer on, it may stop during its operation.

Setting the end days and time for the frost 

protection operation

Press the FROST PROTECTION 

 button for 4 

seconds or more while the frost protection operation is 
enabled (

 is displayed on the remote controller), to 

enter the setting mode.

 

• The setting mode is indicated on the remote 

controller.

• Select the code number to be set with the TEMP. 

 buttons, and set the start time and end 

time with the TIME 

 buttons.

Code No. 12: End days (default 00) 

13: End times (default 00)

ex)
Code No. 12: 05 

13: 13     = 5 days 13 hours

• Press the SET 

 button to determine the end days 

and times.

• Press the TEST 

 button to exit the setting mode.

Night setback

This function is used to save heating operation during 
specified time zone (sleeping hours, etc.) at night.
• When the NIGHT 

 button is pressed during 

heating (ZONE1 or ZONE2), 

 appears on the 

remote controller and the night setback operation is 
reserved. The set temperature is lowered by 5 °C 
between the set start time and end time.

• To stop the night setback operation, press the 

NIGHT 

 button again to delete the 

 mark 

on the remote controller.

Setting the start time and end time for the 

night setback operation

Press the NIGHT 

 button for 4 seconds or 

more while the night setback operation is enabled (

 

is displayed on the remote controller), to enter the 
setting mode.

 

• The setting mode is indicated on the remote 

controller.

• Select the code number to be set with the TEMP. 

 buttons, and set the start time and end 

time with the TIME 

 buttons.

Code No. 0E: Start time (default 22) 

0F: End time (default 06)

• Press the SET 

 button to determine the start time 

and end time.

• Press the TEST 

 button to exit the setting mode.

Hot water boost

This function is used when temporarily giving priority to 
the hot water supply operation.
The hot water supply operation is performed in 
preference to other operations with a target of the 
preset time (60 minutes) or the preset temperature
 (75 °C). Use this function when hot water is not used 
for a long time or before using a large amount of hot 
water.
• When the HOT WATER BOOST 

 button is 

pressed, the 

 mark appears on the remote 

controller and the hot water boost operation starts. 
When the set time period has passed or the water 
temperature has reached the set temperature, the 
hot water boost operation ends automatically.

• The preferential time and temperature settings can 

be changed to values within a range of 30 to 180 
minutes and 40 to 80 °C. Ask the installation 
company to make the required changes to the 
settings.

9-EN

Содержание HWS-1404XWHM3-E1

Страница 1: ...AIR TO WATER HEAT PUMP Hydro Unit Model name HWS 804XWHM3 E1 HWS 804XWHT6 E1 HWS 804XWHT9 E1 HWS 1404XWHM3 E1 HWS 1404XWHT6 E1 HWS 1404XWHT9 E1 Owner s Manual English ...

Страница 2: ...e read this owner s manual carefully before using the system Be sure to obtain the Owner s manual and Installation manual from constructor or dealer Request to constructor or dealer Please clearly explain the contents of the Owner s manual before handing it over to the Customer ADOPTION OF NEW REFRIGERANT This Air to Water Heat Pump is a new type which adopts a new refrigerant HFC R410A instead of...

Страница 3: ...here is a suspected problem with the operation of the Air to Water Heat Pump continuous operation is not recommended operational failures may lead to machine breakdown electric shock a fire etc Do not spill water or other liquid onto the Hydro Unit If the unit is wet it could cause an electric shock Warnings at movement and repair Do not attempt to move or repair the unit yourself Due to the prese...

Страница 4: ...instructions Failure to do so may cause malfunction break down or water to leak from the unit Clear away snow before it accumulates on the outdoor unit Accumulated snow can lead to malfunction and damage Do not locate other electric appliances or furniture underneath the unit Water may drip from the unit which could lead to rust unit failure and damage to property Do not allow the obstruction of a...

Страница 5: ...eration setting 7 STEP button Specifies switching STEP number in a day for weekly schedule 8 TEST button Used for test run or service 9 FROST PROTECTION button Controls minimum operation for unused period going out absence etc for anti freezing 10 NIGHT button Controls the night set back operation 11 AUTO TEMP button Switches setting temperature automatically according to outside temperature Press...

Страница 6: ...er heater is energised during hot water operation Lights when heating is selected Lights during hot water supply operation Lights when cooling is selected Lights while hot water boost is activated Lights when the FROST PROTECTION button is pressed and goes out when the button is pressed again Lights when the ANTI BACTERIA button is pressed and goes out when the button is pressed again Lights when ...

Страница 7: ...am is set Lights during time setting and scheduled operation setting 21 Indication Description Lights while internal pump pump 1 or expansion pump pump 2 is driven Lights when the auxiliary boiler or external booster heater supports the heat pump operation Lights when the unit enters the data set mode and goes out when the unit exits the data set mode Lights when the unit enters the service mode a...

Страница 8: ...n Performing heating or cooling operation Press the ZONE1 2 button to start heating or cooling operation The set temperature appears under on the remote controller When ZONE2 is provided the set temperature appears simultaneously under During the heat pump operation or while the internal heater or backup heater is energized is displayed Use the OPERATE MODE button to select cooling operation or he...

Страница 9: ... 3 2 1 0 1 2 3 4 or 5 Only ZONE1 temperature is displayed When the SET button is pressed after the temperature is changed the set temperature is registered When the TEST button is pressed the registered data is determined The unit exits the function code setting mode and A appears on the display Each time AUTO TEMP button is pressed the mode changes as follows Hot water Performing hot water supply...

Страница 10: ...heating operation during specified time zone sleeping hours etc at night When the NIGHT button is pressed during heating ZONE1 or ZONE2 appears on the remote controller and the night setback operation is reserved The set temperature is lowered by 5 C between the set start time and end time To stop the night setback operation press the NIGHT button again to delete the mark on the remote controller ...

Страница 11: ...ek Example Monday Tuesday to Saturday Same as Monday Sunday Setting the schedule function Press the SCHEDULE button and press the SET button within five seconds while the mark is blinking The mark changes to lighting and the schedule function starts working Cancelling the schedule function Press the SCHEDULE button and press the CL button within five seconds while the mark is blinking The mark dis...

Страница 12: ...et is displayed 4 Set temperature Set the temperature for ZONE1 or ZONE2 with the SELECT button and TEMP buttons Press the SELECT button so that the mark lights for the zone to be changed Enter setting temperature with the TEMP buttons 5 Set operation mode Set the operation mode heating or cooling with the OPERATE MODE button 6 Determine the settings Press the SET button to determine the settings ...

Страница 13: ...side and brought into the room This way of heating is called heat pump system When the outside temperature is too low it is recommended to use another heating apparatus in combination with the air to water heat pump Attention to snowfall and freeze on the outdoor unit In snowy areas the air intake and air discharge of the outdoor unit are often covered with snow or frozen up If snow or freeze on t...

Страница 14: ...0 11 2 14 0 16 0 Input kW 2 34 3 16 3 72 2 34 3 16 3 72 COP 4 80 4 44 4 30 4 80 4 44 4 30 Cooling Capacity kW 10 0 11 0 13 0 10 0 11 0 13 0 Input kW 3 26 3 81 4 80 3 26 3 81 4 80 EER 3 07 2 89 2 71 3 07 2 89 2 71 Refrigerant R410A Dimension HxWxD mm 1 340x900x320 Cord heater W 75 Hydro Unit HWS 804XWHM3 E1 HWS 804XWHT6 E1 HWS 804XWHT9 E1 Back up heater capacity 3 0 6 0 9 0 Power supply for back up...

Страница 15: ...witch turned on Time indication is blinking Date time setting is not made Set date and time An error code is displayed on the remote controller Contact the installation company Room is not cooled or heated Is scheduled operation set Check whether scheduled operation is set Is night setback operation set Check the setting on the remote controller Is the air to water heat pump operating in Auto mode...

Страница 16: ... manufacturer TOSHIBA CARRIER CORPORATION Address city country 336 Tadehara Fuji shi Shizuoka ken 416 8521 Japan Name of the Importer Distributor in EU Toshiba Carrier UK Ltd Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom ...