Hydro Unit

Owner’s Manual

1

Safety precautions

DANGER

Do not attempt to install this unit yourself. 

This unit requires a qualified installer.

Do not attempt to repair the unit yourself.

This unit has no components which you can repair.

Opening or removing the cover will expose you to dangerous voltages.

Turning off the power supply will prevent potential electric shock.

WARNING

Installation warnings

• Be sure to ask a dealer or a store specialized in electrical work to install the Air to Water Heat Pump.

• The Air to Water Heat Pump should be installed by a suitably qualified installer, if not; this may lead to problems such as 

water leaks, electric shock, fire, etc.

• Ensure the correct grounding procedures are applied when installing the Air to Water Heat Pump.

• Do not connect the earth wire to gas pipes, water pipes, lightning rods or telephone earth wires.

• Should the Air to Water Heat Pump be improperly grounded, this could lead to an electric shock.

• Serious damage can occur if there is water leak. Therefore, the Hydro Unit is recommended to be installed in a room with 

waterproof flooring and drainage systems.

• Products and parts to be used in combination with this product must be specified products and parts that meet prescribed 

specifications. If unspecified products or parts are used, a failure, smoke, fire, or electric shock may be caused.

Operation warnings

• Avoid injury or damage to the outdoor unit by never inserting fingers or sticks into the air discharge or air intake of the 

outdoor unit, during operation the fans run at a high speed.

• Should you notice something unusual with the Air to Water Heat Pump (such as a burning smell or low heating power), 

immediately turn off the main switch and circuit breaker from the main power supply to stop the Air to Water Heat Pump, 

and contact the dealer.

• If there is a suspected problem with the operation of the Air to Water Heat Pump, continuous operation is not recommended, 

operational failures may lead to machine breakdown, electric shock, a fire, etc.

• Do not spill water or other liquid onto the Hydro Unit.

• If the unit is wet, it could cause an electric shock.

Warnings at movement and repair

• Do not attempt to move or repair the unit yourself.

• Due to the presence of high voltage, removal of any covers may result in an electric shock.

• Should there be any requirements for the Air to Water Heat Pump to be moved, always consult the dealer or qualified 

installer.

• Should the Air to Water Heat Pump be improperly installed, it may lead to electric shock or fire.

• Whenever the Air to Water Heat Pump requires repair, request assistance from the dealer.

• Should the Air to Water Heat Pump be improperly repaired, the result may lead to electric shock or fire.

CAUTION

This appliance is not intended for use by person (including children) with reduced physical sensory or mental 
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning 
use of the appliance by a person responsible for their safety.

To disconnect the appliance from the main power supply

This appliance must be connected to the main power supply using a circuit breaker or switch with a contact separation 
of at least 3 mm.

Installation cautions

• Be sure to connect the Air to Water Heat Pump to a dedicated power supply using the rated voltage.

Failure to do so may cause the unit to break down or cause a fire.

• Do not install the unit in a place where there is a risk that flammable gas may leak.

• An accumulation of flammable gases around the unit may result in a fire.

Operation cautions

• To ensure satisfactory performance, please read this manual carefully before operating the Air to Water Heat Pump system.

• Do not install the Air to Water Heat Pump in special-purpose rooms such as a ship or any kind of vehicle.

Doing so could harm machine performance.

2-EN

Содержание HWS-1404XWHM3-E

Страница 1: ...AIR TO WATER HEAT PUMP Hydro Unit Model name HWS 804XWHM3 E HWS 804XWHT6 E HWS 804XWHT9 E HWS 1404XWHM3 E HWS 1404XWHT6 E HWS 1404XWHT9 E Owner s Manual English ...

Страница 2: ...e read this owner s manual carefully before using the system Be sure to obtain the Owner s manual and Installation manual from constructor or dealer Request to constructor or dealer Please clearly explain the contents of the Owner s manual before handing it over to the Customer ADOPTION OF NEW REFRIGERANT This Air to Water Heat Pump is a new type which adopts a new refrigerant HFC R410A instead of...

Страница 3: ...here is a suspected problem with the operation of the Air to Water Heat Pump continuous operation is not recommended operational failures may lead to machine breakdown electric shock a fire etc Do not spill water or other liquid onto the Hydro Unit If the unit is wet it could cause an electric shock Warnings at movement and repair Do not attempt to move or repair the unit yourself Due to the prese...

Страница 4: ...instructions Failure to do so may cause malfunction break down or water to leak from the unit Clear away snow before it accumulates on the outdoor unit Accumulated snow can lead to malfunction and damage Do not locate other electric appliances or furniture underneath the unit Water may drip from the unit which could lead to rust unit failure and damage to property Do not allow the obstruction of a...

Страница 5: ...eration setting 7 STEP button Specifies switching STEP number in a day for weekly schedule 8 TEST button Used for test run or service 9 FROST PROTECTION button Controls minimum operation for unused period going out absence etc for anti freezing 10 NIGHT button Controls the night set back operation 11 AUTO TEMP button Switches setting temperature automatically according to outside temperature Press...

Страница 6: ...er heater is energised during hot water operation Lights when heating is selected Lights during hot water supply operation Lights when cooling is selected Lights while hot water boost is activated Lights when the FROST PROTECTION button is pressed and goes out when the button is pressed again Lights when the ANTI BACTERIA button is pressed and goes out when the button is pressed again Lights when ...

Страница 7: ...am is set Lights during time setting and scheduled operation setting 21 Indication Description Lights while internal pump pump 1 or expansion pump pump 2 is driven Lights when the auxiliary boiler or external booster heater supports the heat pump operation Lights when the unit enters the data set mode and goes out when the unit exits the data set mode Lights when the unit enters the service mode a...

Страница 8: ...n Performing heating or cooling operation Press the ZONE1 2 button to start heating or cooling operation The set temperature appears under on the remote controller When ZONE2 is provided the set temperature appears simultaneously under During the heat pump operation or while the internal heater or backup heater is energized is displayed Use the OPERATE MODE button to select cooling operation or he...

Страница 9: ...5 4 3 2 1 0 1 2 3 4 or 5 Only ZONE1 temperature is displayed When the SET button is pressed after the temperature is changed the set temperature is registered When the TEST button is pressed the registered data is determined The unit exits the function code setting mode and A appears on the display Each time AUTO TEMP button is pressed the mode changes as follows Hot water Performing hot water sup...

Страница 10: ...st protection is operated with schedule timer on it may stop during its operation Setting the end days and time for the frost protection operation Press the FROST PROTECTION button for 4 seconds or more while the frost protection operation is enabled is displayed on the remote controller to enter the setting mode The setting mode is indicated on the remote controller Select the code number to be s...

Страница 11: ...ek Example Monday Tuesday to Saturday Same as Monday Sunday Setting the schedule function Press the SCHEDULE button and press the SET button within five seconds while the mark is blinking The mark changes to lighting and the schedule function starts working Cancelling the schedule function Press the SCHEDULE button and press the CL button within five seconds while the mark is blinking The mark dis...

Страница 12: ...et is displayed 4 Set temperature Set the temperature for ZONE1 or ZONE2 with the SELECT button and TEMP buttons Press the SELECT button so that the mark lights for the zone to be changed Enter setting temperature with the TEMP buttons 5 Set operation mode Set the operation mode heating or cooling with the OPERATE MODE button 6 Determine the settings Press the SET button to determine the settings ...

Страница 13: ...rbed from the outside and brought into the room This way of heating is called heat pump system When the outside temperature is too low it is recommended to use another heating apparatus in combination with the air to water heat pump Attention to snowfall and freeze on the outdoor unit In snowy areas the air intake and air discharge of the outdoor unit are often covered with snow or frozen up If sn...

Страница 14: ...0 16 0 11 2 14 0 16 0 Input kW 2 34 3 16 3 72 2 34 3 16 3 72 COP 4 80 4 44 4 30 4 80 4 44 4 30 Cooling Capacity kW 10 0 11 0 13 0 10 0 11 0 13 0 Input kW 3 26 3 81 4 80 3 26 3 81 4 80 EER 3 07 2 89 2 71 3 07 2 89 2 71 Refrigerant R410A Dimension HxWxD mm 1 340x900x320 Cord heater W 75 Hydro Unit HWS 804XWHM3 E HWS 804XWHT6 E HWS 804XWHT9 E Back up heater capacity 3 0 6 0 9 0 Power supply for back ...

Страница 15: ...itch turned on Time indication is blinking Date time setting is not made Set date and time An error code is displayed on the remote controller Contact the installation company Room is not cooled or heated Is scheduled operation set Check whether scheduled operation is set Is night setback operation set Check the setting on the remote controller Is the air to water heat pump operating in Auto mode ...

Страница 16: ... manufacturer TOSHIBA CARRIER CORPORATION Address city country 336 Tadehara Fuji shi Shizuoka ken 416 8521 Japan Name of the Importer Distributor in EU Toshiba Carrier UK Ltd Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom ...

Отзывы: