background image

EJL-146C 

2

 

Ambient temperature: 

14 to 140 °F (-10 to +60

 
Storage temperature:
 

5 to 149 °F (-15 to +65

 
Storage humidity:
 

10 to 90%RH (no condensation) 

 
Structure: 

IP67 and NEMA 4 Watertight 
*IP68 and NEMA 6P is available as option. 

 
Power consumption: 

10W  (14VA)  or  less  (at  AC100V  and  Excitation 
current 0.2A) 
17W (24VA) or less (with communication) 

 
Meter size: 

ANSI 150 

20”, 24”(500, 600m) 

AWWA class D 

28”,  32”,  36”  40”,  48”,  54”,  66”,  72”,  78”,  80” 
(700,  800,  900,  1000,  1200,  1350,  1650,  1800, 
1950mm) 

EN1092-1, GB9119 

500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 
1800, 2000mm 

 
Fluid pressure: 

-0.1MPa  to  the  pressure  limited  by  the connection 
flange 

 
Connection flange standard: 

See Table 4 Type Specification Code 

 
Principal materials: 

Case 

Carbon steel 

Lining 

Natural rubber 

Electrodes 

AISI 316L (std.) 

 

Titanium (opt.) 

 

Hastelloy C equivalent (opt.) 

Grounding rings 

None 

 
Coating: 

Polyurethane, gray colored 

 
Terminal Box: 

Housing: 

Aluminum alloy 

G(PF) 1/2 thread, Cable glands provided   
(Applicable cable diameter : 0.354 to 0.551 inch(9 
to 14 mm)) 

 
 
 
 

 

Specifications  of  LF622(Separate  type) 
Converter

 

Input signals: 

Analog signal: 

The voltage signal from detector. 
Proportional to process flow rate 

Digital input DI: 

Signal type: 

20 to 30Vdc voltage signal 

Input resistance:  2.7k

 

Number of inputs: one point 
Note:  DI  cannot  be  used  with  the  Modbus 

communication. 

DI function: 

One  of  the  following  functions  can  be  assigned 
to the optional DI signal. 

Range switching 

Selects either the higher or lower range in the 

unidirectional or bidirectional 

2-range setting. 

Totalizer control 

Starts and stops the built-in totalizer. 

Fixed-value outputs 

Outputs  fixed-values  for  current  and  pulse 

outputs. 

Zero adjustment 

Executes  zero  adjustment  (on-stream  at  zero 
flow rate). 

Output signals: 

Current output:   

4-20mAdc (load resistance 0 to 750

Note:  The  current  output  cannot  be  used  with 

the 

PROFIBUS 

and 

Modbus 

communication. 

Digital outputs: 

Two points are available as follows. 
Digital output DO1: 

Output type: Transistor open collector 
Number of outputs: One point 
Output capacity: 30Vdc, 200mA maximum 
Note:  DO1  cannot  be  used  if  Modbus 

communication  connection  is  3 
lines. 

Digital output DO2: 

Output  type:  Solid-state  relay  output  (non 

polarity) 

Number of outputs: One point 
Output  capacity:  150Vdc,  150mA  maximum 

or  150Vac  (peak  to  peak), 
100mA maximum 

Note: DO2 cannot be used with the Modbus 

communication. 

DO1 and DO2 functions: 

One  of  the  following  functions  can  be  assigned 
to DO1 and/or DO2. 
 
 

Содержание GF642

Страница 1: ...r Modbus 3 interface is available as an option 1 HART protocol Highway Addressable Remote Transducer is a communication protocol for industrial sensors recommended by the HCF HART Communication Foundation 2 PROFIBUS is the communications protocol for factory and process automation that the PROFIBUS Organization recommends Instead of analog control with a conventional analog signal 4 20 mA it is fi...

Страница 2: ...al to process flow rate Digital input DI Signal type 20 to 30Vdc voltage signal Input resistance 2 7kΩ Number of inputs one point Note DI cannot be used with the Modbus communication DI function One of the following functions can be assigned to the optional DI signal Range switching Selects either the higher or lower range in the unidirectional or bidirectional 2 range setting Totalizer control St...

Страница 3: ... This length is specification of 3 line connection LCD display Full dot matrix 128 128 dot LCD display back light provided Parameter setting Parameters can be set as follows IR Switches Tree key switches are provided to set configuration parameters Digital communication The AF900 hand held terminal or PROFIBUS Modbus is needed to set parameters Zero adjustment Zero point adjustment can be started ...

Страница 4: ...ce to the following levels of vibration 10 to 150Hz with acceleration of 9 8m s2 Vibration of 30Hz with 29 4m s2 in 4h in each direction will not cause any defect to unit Note Avoid using the flowmeter in an environment with constant vibration ...

Страница 5: ... 78 78 7 46 5 87 6615 DIN PN6 GB 0 6MPa DIN PN10 GB 1 0MPa Size mm L1 L2 L3 Weight kg approx Size mm L1 L2 L3 Weight kg approx 500 500 600 417 752 210 600 600 600 455 845 260 700 700 517 947 260 700 700 517 965 270 800 800 569 1057 350 800 800 569 1077 380 900 900 620 1157 400 900 900 620 1177 450 1000 1000 670 1257 450 1000 1000 670 1285 550 1200 1200 770 1473 650 1200 1200 770 1498 850 1400 1400...

Страница 6: ...3 wire shielded hard rubber cable Thick walled steel conduit Power switch External double pole power switch Symbol Description Cable L1 Power supply Power cable L2 GND Ground for arrester FG Frame ground DI Digital Input 20 30Vdc I O cable DO1 Digital Output 1 DO2 Digital Output 2 COM Signal Common for DI DO1 DO2 Current Output 4 20mAdc or PROFIBUS Shielded cable for PROFIBUS PA X Excitation cable...

Страница 7: ...meter will not be affected by lightning etc 6 The electromagnetic flowmeter is not equipped with terminating resistors in the PROFIBUS communication Use the terminating resistor unit for PROFIBUS PAor junction box if necessary 7 Please install the terminator bundling in the electromagnetic flowmeter connected with the end in the Modbus communication 8 When wiring is completed male sure to install ...

Страница 8: ...otrudes into the detector pipe L 0 L Required straight pipe length D Meter size Piping materials to be ordered separately Mating flanges The flowmeter must be mounted with its detector pipe connected between the flanges in the pipeline If no flanges are used where the flowmeter is to be mounted mating flanges are needed Adjustable short pipe When both the upstream and downstream pipe sections cann...

Страница 9: ...A 7 1650mm A 8 1800mm A 9 1950mm B 0 2000mm Connection flange standard A ANSI 150 AWWA class D 1 F EN 1092 1 PN6 DIN C EN 1092 1 PN10 DIN G GB 9119 0 6MPa H GB 9119 1 0MPa Lining N Natural rubber Electrode material K AISI316L C Titanium F Hastelloy C equivalent Roll prevention Base A Base not provided B Base provided 1 Standard Code explanation Standard Option Not available A ANSI 150 AWWA class D...

Страница 10: ...dc 3 110Vdc Instruction manual F English Code explanation Standard Option Note 1 When Modbus communication is provided digital output points 1 DO1 and digital output points DO2 digital input point 1 DI HART communication cannot be used When PROFIBUS communication is provided current output 4 20mA and HART communication cannot be used Check Table 6 for the details Note 2 Select 110Vdc for test repo...

Страница 11: ...mm for 2mm2 13mm 2 Signal cable is a 2 wire shielded chloroprene sheathed cable with a nominal cross sectional area of 0 75mm2 and an overall diameter of 12mm 3 Relation between exciting cable length and its nominal cross sectional area and overall diameter is as follows Exciting cable length Nominal cross sectional area Overall diameter 1 to 200m 1 25mm2 12mm 210 to 300m 2mm2 13mm From 1 to 10met...

Отзывы: