a &a
Transmitter
Unit
Nominal
Limit
RF Power (50
Ω
Load)
dBm
−
7
−
10 ~
−
4
Modulation Sensitivity
mV
10.5
7 ~ 15
Frequency Response
0.3 kHz
dB
−
1
−
5 ~ +3
3.0 kHz
dB
−
1.5
−
5.5 ~ +2.5
Frequency Tolerance (25 °C)
Hz
0
±
1500
Code Deviation
kHz
8
< 11
Distortion
%
1
< 5
Adjacent CH Power
(Input 130 mV, 50 KHz Offset, 25 KHz BW)
(+)
dB
55
> 50
(
−
)
dB
55
> 50
S/N Ratio
(CCITT Filter ON, Compander ON)
dB
40
> 35
Power Consumption
Base Unit
a. Standby Charge Off
mA
70
< 90
b. Standby Charge ON
mA
165
150 ~ 190
c. Talk
mA
110
< 130
Charge Current (at CHG CONTACT)
mA
90
80 ~ 100
Portable Unit
a. Stand-by
mA
3.4
< 4
b. Talk
mA
85
< 100
Battery Low Detect Voltage
V
3.3
3.0 ~ 3.6
Battery:
Ni-Cd Battery 600 mAH (@1.2 V
×
3 = 3.6)
Memory:
10 Memories (16 Digits) + 1 Redial Memory (32 Digits)
Operating Temperature:
−
10 °C ~ 50°C
Storage Temperature:
−
20 °C ~ 60°C
Requirements Compliance
Unit is designed to fully meet with UL1459 and FCC Rules, Part 15 and 68.