9
© 2012-2013 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2555C/3055C/3555C/4555C/5055C
REPLACEMENT OF PC BOARDS/HDD
9 - 5
9.1.5
IH board
Notes:
Be sure to unplug the power cable before starting this work.
(1)
Remove the SYS board case.
(2)
Remove 3 screws and take off the IH board
cover [1].
Fig. 9-12
(3)
Disconnect the 3 connectors [1].
(4)
Remove 1 screw for each, and take off 2 IH
feed terminals [2].
Notes:
When connecting connectors, be careful not
to confuse the white connector location with
the black connector location. To connect 2
harnesses to the IH coil, you do not need to
make a distinction between the upper and
lower sides.
When installing, securely tighten the fixing
screw of the IH feed terminal [2] so that it
does not bexome loose.
Fig. 9-13
Notes:
Wire the IH harness as shown in the figure
and secure the terminals horizontally.
Fig. 9-14
Содержание e-studio 2555c
Страница 6: ......
Страница 10: ......
Страница 24: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FEATURE 1 2 ...
Страница 426: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved SELF DIAGNOSTIC MODE 5 60 ...
Страница 1008: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 24 Fig 11 14 ...
Страница 1024: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 40 ...
Страница 1038: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 12 14 ...
Страница 1044: ...e STUDIO2555C 3055C 3555C 4555C 5055C 2012 2013 TOSHIBA TEC CORPORATION All rights reserved EXTERNAL COUNTERS 13 6 ...
Страница 1550: ......
Страница 1557: ......
Страница 1558: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...