e-STUDIO200L/202L/230/232/280/282 POWER SUPPLY UNIT
June 2004 © TOSHIBA TEC
16 - 2
16.2 Operation of DC Output Circuits
1) Starting line output
When the main switch of the equipment is turned ON, power starts supplying to all the lines only
when two doors (front cover and transfer guide) are closed.
2) Stopping line output
When the main switch of the equipment is turned OFF, PWR-DN signal is output after the instanta-
neous outage insurance time (20 ms or more) elapses and then the supply of each voltage stops. If
the supply of voltage of the main line (+3.3VA, +5.1VA, +12VA, -12VA) stops earlier than the 24V
line does, it may cause the damage of the electron device on each control circuit. To prevent this,
the supply of these voltages stops after the PWR-DN signal is output and the minimum retaining
time (+3.3VA/+5.1VA: 50 ms or more, +12VA/-12VA: 5 ms or more) elapses.
3) Output protection
Each output system includes an overcurrent and overvoltage protection circuits (a fuse and internal
protection circuit). This is to prevent the defectives (damage or abnormal operation of the secondary
circuit) which may be caused by an overcurrent due to a short circuit or an overvoltage due to a
short circuit between different voltages. If the protection circuit is activated (except the case the fuse
is blown out), remove the causes such as short-circuit. Turn ON the power again 1 minute later to
clear the overcurrent protection.
Содержание e-studio 202L
Страница 6: ......
Страница 10: ...e STUDIO200L 202L 230 232 280 282 CONTENTS June 2004 TOSHIBA TEC 4 ...
Страница 34: ...e STUDIO200L 202L 230 232 280 282 SPECIFICATIONS ACCESSORIES OPTIONS SUPPLIES June 2004 TOSHIBA TEC 1 24 ...
Страница 118: ...e STUDIO200L 202L 230 232 280 282 COPY PROCESS June 2004 TOSHIBA TEC 3 14 ...
Страница 134: ...e STUDIO200L 202L 230 232 280 282 GENERAL OPERATION June 2004 TOSHIBA TEC 4 16 ...
Страница 156: ...e STUDIO200L 202L 230 232 280 282 CONTROL PANEL June 2004 TOSHIBA TEC 5 22 ...
Страница 194: ...e STUDIO200L 202L 230 232 280 282 IMAGE PROCESSING June 2004 TOSHIBA TEC 7 10 ...
Страница 206: ...e STUDIO200L 202L 230 232 280 282 LASER OPTICAL UNIT June 2004 TOSHIBA TEC 8 12 ...
Страница 242: ...e STUDIO200L 202L 230 232 280 282 PAPER FEEDING SYSTEM June 2004 TOSHIBA TEC 9 36 ...
Страница 316: ...e STUDIO200L 202L 230 232 280 282 PAPER EXIT SECTION June 2004 TOSHIBA TEC 14 8 ...
Страница 344: ...e STUDIO200L 202L 230 232 280 282 PC BOARDS June 2004 TOSHIBA TEC 17 2 e STUDIO202L 232 232S 282 282S 05 11 ...
Страница 352: ...e STUDIO200L 202L 230 232 280 282 PC BOARDS June 2004 TOSHIBA TEC 17 10 ...
Страница 353: ......
Страница 354: ......