44
Work flow timing chart: Glass
exist or not countdown
1/0
48'
Normal
Abnormal
1
Inlet water
Detected buoy
1
0
bee bee alarm
"EF" error
2
Drain
10S#
0
0
-
-
3
Inlet water
0.2L*
0
0
-
-
4
Drain
10S
0
0
-
-
5
Inlet water
0.2L
0
0
-
-
6
Drain
20S
0
1
-
-
7
Discharge water
1.5L
1
0
water in tub
"E1" error
8
Wash heat
T60
1
8
water heated
"E3" error
9
Wash
300
1
5
-
-
10
Wash heat
T60/120S^
1
2
-
-
11
Wash
300S
1
5
-
-
12
Wash heat
T60/120S
1
2
-
-
13
Wash
120S
1
3
-
-
14
Drain
8S
1
0
-
-
15
Static
3S
1
0
-
-
16
Drain
5S
1
0
Drain
No drain
17
Static
3S
1
0
-
-
18
Drain
10S
1
1
-
-
19
放水
1.3L
1
0
-
-
20
Wash
180S
1
3
-
-
21
Drain
8S
1
0
-
-
22
Static
3S
1
0
-
-
23
Drain
5S
1
0
-
-
24
Static
3S
1
0
-
-
25
Drain
10S
1
0
-
-
26
Discharge water
1.3L
1
0
water in tub
"E1" error
27
Wash heat
T50
1
3
water heated
"E3" error
28
Wash heat
60S
1
1
-
-
29
Wash heat
T60
1
3
-
-
30
Wash
120S
1
2
-
-
31
Drain
8S
1
0
32
Static
3S
1
0
-
-
33
Drain
5S
1
0
-
-
34
Static
3S
1
0
-
-
35
Drain
10S
1
0
-
-
36
Static
10S
1
0
-
-
37
Fan
420S
1
7
Fan active
Fan static
38
Drain
10S
1
1
-
-
39
Drain
Pulse detecting
1
0
-
-
40
Regeneration
30S
0
0
-
-
41
Drain
30S
1
1
-
-
# This step commands the execution time,unit"second"
* This step command performs water entry,unit"litre"
^This step executes the command to heat to the set temperature,unit"℃", Or reach the set time ,unit"second"
Main
wash
Rinse
Dry
NO. Phase
Step
Parameter
Phenomenon