background image

No. MIIXR0002EAC 

8  X-Ray Angiographic Information Object Definition 

 

8.1  Entity Module Definitions 

The information modules for the X-Ray Angiographic devices are defined below. 

8.1.1 Media 

Storage 

Directory IOD Modules 

Table 5 

Object 

Module / key 

Reference

Usage

1

 

DICOM File Meta 
Information 

 8.2.1 

File-set Identification Module 

8.3.1 

Basic Directory 
Information Object 
Definition 

Directory Information Module 

8.3.2 

PATIENT keys 

8.4.1 

STUDY keys 

8.4.2 

SERIES keys 

8.4.3 

Definition of Specific 
Directory Records 

IMAGE keys 

8.4.4 

 

1

 M=Mandatory, C=Conditional, U=User option 

 

8.1.2  Media Storage XA IOD Modules 

Table 6 

Object 

Module / key 

Reference

Usage

1

 

DICOM File Meta 
Information 

 8.2.2 

XA Information 
Object Definition 

XA IOD Modules 

8.1.3 

 

1

 M=Mandatory, C=Conditional, U=User option 

 

- 9 -

 

Содержание DFP-2000A

Страница 1: ...No MIIXR0002EAC DICOM CONFORMANCE STATEMENT MEDIA STORAGE FOR TOSHIBA DIGITAL FLUOROGRAPHY SYSTEM MODEL DFP 2000A with XIDF 037A and XIDF 038A or SRS 1000A MIIXR0002EAC 2001 ...

Страница 2: ...IMPORTANT 1 No part of this manual may be copied or reprinted in whole or in part without written permission 2 The contents of this manual are subject to change without prior notice and without our legal obligation C 1 ...

Страница 3: ...tivity 6 3 1 2 1 Real World Activity Transfer of X ray Examination 6 3 1 3 Media Storage Application Profile 6 3 1 4 Information Object Definition and DICOMDIR keys 6 3 2 DICOM READER SPECIFICATION 6 3 2 1 File Meta Information for the Application Entity 7 3 2 2 Real World Activity 7 3 2 2 1 Real World Activity Review of X ray Examination 7 3 2 3 Media Storage Application Profile 7 3 2 4 Informati...

Страница 4: ...CIFIC DIRECTORY RECORDS 12 8 4 1 PATIENT keys 12 8 4 2 STUDY keys 13 8 4 3 SERIES keys 13 8 4 4 IMAGE keys 14 8 5 XA INFORMATION OBJECT DEFINISIONS 15 8 5 1 Patient Module 15 8 5 2 General Study Module 15 8 5 3 Patient Study Module 15 8 5 4 General Series Module 16 8 5 5 General Equipment Module 16 8 5 6 General Image Module 16 8 5 7 Image Pixel Module 17 8 5 8 Contrast Bolus Module 17 8 5 9 Cine ...

Страница 5: ...Information Object Definition IOD An IOD is a data model which is an abstraction of real world information This data model defines the nature and attributes relevant to the class of real world objects represented Service Object Pair SOP Class A SOP Class is defined by the union of an Information Object Definition and a set of DIMSE Services A DICOM Application Entity may support one or more SOP Cl...

Страница 6: ...rofile CEN TC251 Comite Europeen de Normalisation Technical Committee 251 Medical Informatics DICOM Digital Imaging and Communications in Medicine FSC File set Creator FSR File set Reader FSU File set Updater IOD Information Object Definition ISO International Standards Organization JIRA Japan Industries Association of Radiological Systems NEMA National Electrical Manufacturers Association RWA Rea...

Страница 7: ...der FSR Local Relationship Figure 1 2 2 Functional Definitions of AE s 2 2 1 DICOM Recording The DICOM Recording supports the following tasks Builds DICOM XA Information Objects Creates a DICOMDIR file that represents the contents of DICOM XA Information Objects to be recorded Records DICOM XA Information Objects and DICOMDIR from the local storage to the CD R media Duplicates the File set of the ...

Страница 8: ...e to be recorded When the size of images exceeds the capacity of a single CD R the request of transferring images is canceled Each CD R media has a DICOMDIR file that represents the contents of the data as recorded Operator can request to duplicate the CD R media from the recorded CD R media to the blank CD R media 2 3 1 2 Review of X ray Examination Operator inserts the CD R media to be read Oper...

Страница 9: ...onto the CD R media 2 3 2 2 Review of X ray Examination The operation for manual review of X ray examination is described below STEP 1 Insert the CD R media to be review STEP 2 Select one image from the list or from the thumbnail images STEP 3 Request forward play backward play step by step or other image processings 2 4 File Meta Information for Implementation Class and Version File Meta Informat...

Страница 10: ...1 2 1 Real World Activity Transfer of X ray Examination DICOM Recording AE acts as a FSC when chosen by the operator This AE writes the SOP instances onto the CD R media creates a DICOMDIR and writes it onto the CD R media 3 1 3 Media Storage Application Profile DICOM Recording AE uses the Application Profile defined in Table 1 3 1 4 Information Object Definition and DICOMDIR keys Information Obje...

Страница 11: ...n and DICOMDIR keys Information Object Definition and DICOMDIR keys are described in Chapter 8 4 Augmented and Private Application Profiles 4 1 Augmented Application Profiles DICOM Reader AE supports Augmented Application Profile AUG XABC CD This is a extension of the standard Application Profile STD XABC CD 4 1 1 AUG XABC CD 4 1 1 1 SOP Class Augmentations None 4 1 1 2 Directory Augmentations Non...

Страница 12: ...onfiguration For the Digital Fluorography System the configuration can be set Note Settings and changes are performed by Toshiba Service Personnel at the time of installation of the Digital Fluorography System 7 Support of Extended Character Sets This product supports the following character sets Table 4 ISO IR 6 default Basic G0 Set 8 ...

Страница 13: ...File set Identification Module 8 3 1 M Basic Directory Information Object Definition Directory Information Module 8 3 2 U PATIENT keys 8 4 1 M STUDY keys 8 4 2 M SERIES keys 8 4 3 M Definition of Specific Directory Records IMAGE keys 8 4 4 M 1 M Mandatory C Conditional U User option 8 1 2 Media Storage XA IOD Modules Table 6 Object Module key Reference Usage1 DICOM File Meta Information 8 2 2 M XA...

Страница 14: ...inters Module Not Used U Image Mask Module Not Used C Image Display Shutter Module Not Used U Image Device Module Not Used U Image Therapy Module Not Used U Image X ray Image Module 8 5 11 M Image X ray Acquisition Module 8 5 12 M Image X ray Collimator Module Not Used U Image X ray Table Module Not Used C Image XA Positioner Module 8 5 13 M Image Overlay Plane Module Not Used U Image Multi Frame ...

Страница 15: ...ys set 8 2 2 DICOM File Meta Information of XA IOD Table 9 Attribute Name Tag Type Attribute Description File Preamble No Tag 1 Always set DICOM Prefix No Tag 1 Always set DICM Group Length 0002 0000 1 Always set File Meta Information Version 0002 0001 1 Always set 0x0001 Media Storage SOP Class UID 0002 0002 1 Always set 1 2 840 10008 5 1 4 1 1 12 1 Media Storage SOP Instance UID 0002 0003 1 Alwa...

Страница 16: ...Directory Entity 0004 1420 1C Always set when condition is met Directory Record Type 0004 1430 1C Always set when condition is met Referenced File ID 0004 1500 1C Always set when condition is met Referenced SOP Class UID in File 0004 1510 1C Always set when condition is met Referenced SOP Instance UID in File 0004 1511 1C Always set when condition is met Referenced Transfer Syntax UID in File 0004...

Страница 17: ...C Always set Study ID 0020 0010 1 Always set Accession Number 0008 0050 2 Length 0 when no entry is made 8 4 3 SERIES keys Table 14 Attribute Name Tag Type Attribute Description Modality 0008 0060 1 Always set XA Series Instance UID 0020 000E 1 Always set Series Number 0020 0011 1 Always set Institution Name 0008 0080 2 Always set Institution Address 0008 0081 2 Always set Performing Physician s N...

Страница 18: ...0 4000 3 Length 0 when no entry is made Number of Frames 0028 0008 3 Always set Calibration Image 0050 0004 2 Always set Icon Image Sequence 0088 0200 1 Always set Samples per Pixel 0028 0002 1 Always set 0x0001 Photometric Interpretation 0028 0004 1 Always set MONOCHROME2 Rows 0028 0010 1 Always set 0x0100 Columns 0028 0011 1 Always set 0x0100 Bits Allocated 0028 0100 1 Always set 0x0008 Bits Sto...

Страница 19: ... Study Module Table 17 Attribute Name Tag Type Attribute Description Study Instance UID 0020 000D 1 Always set Study Date 0008 0020 2 Always set Study Time 0008 0030 2 Always set Referring Physician s Name 0008 0090 2 Length 0 when no entry is made Study ID 0020 0010 2 Always set Accession Number 0008 0050 2 Length 0 when no entry is made Study Description 0008 1030 3 Length 0 when no entry is mad...

Страница 20: ...urer 0008 0070 2 Always set Institution Name 0008 0080 3 Always set Institution Address 0008 0081 3 Always set Station Name 0008 1010 3 Always set Manufacturer s Model Name 0008 1090 3 Always set Device Serial Number 0018 1000 3 Always set Software Versions 0018 1020 3 Always set 8 5 6 General Image Module Table 21 Attribute Name Tag Type Attribute Description Image Number 0020 0013 2 Always set P...

Страница 21: ...set Pixel Data 7FE0 0010 1 Always set 8 5 8 Contrast Bolus Module Table 23 Attribute Name Tag Type Attribute Description Contrast Bolus Agent 0018 0010 2 Length 0 when no entry is made Contrast Bolus Route 0018 1040 3 Length 0 when no entry is made Contrast Bolus Volume 0018 1041 3 Length 0 when no entry is made Contrast Flow Rate s 0018 1046 3 Length 0 when no entry is made 8 5 9 Cine Module Tabl...

Страница 22: ... Sequence 0008 1140 1C Not set when Image type 0008 0008 Value 3 is SINGLE PLANE Reference SOP Class UID 0008 1150 1C Always set when Reference Image Sequence is present Reference SOP Instance UID 0008 1155 1C Always set when Reference Image Sequence is present 8 5 12 X ray Acquisition Module Table 27 Attribute Name Tag Type Attribute Description KVP 0018 0060 2 Always set kV Radiation Setting 001...

Страница 23: ...Number of Points 5000 0010 1 Always set Type of Data 5000 0020 1 Always set Axis Units 5000 0030 3 Always set Data Value Representation 5000 0103 1 Always set Curve Data Descriptor 5000 0110 1C Always set Coordinate Start Value 5000 0112 1C Always set Coordinate Step Value 5000 0114 1C Always set Curve Data 5000 3000 1 Always set Note This module is set only if ECG data is available 8 5 15 VOI LUT...