E658130
- 22 -
■
Input function selection from the CC-Link.
The function numbers selection of the RYn2 to RYn8 function valid from the command of the CC-Link are following
boldface numbers.
Positive logic Negative logic
Function
Speed control PM control
V/f
0
1
No function is assigned
●
/
●
●
●
2
3 Forward
run
command
●
/
●
●
●
4
5 Reverse
run
command
●
/
●
●
●
6
7 Standby
●
/
●
●
●
8
9 Reset
command
●
/
●
●
●
10
11
Preset speed command 1
●
/
●
●
●
12
13
Preset speed command 2
●
/
●
●
●
14
15
Preset speed command 3
●
/
●
●
●
16
17
Preset speed command 4
●
/
●
●
●
18
19 Jog
run
mode
●
/
●
●
●
20
21
Emergency stop by external signal *
●
/
●
●
●
22
23 DC
braking
command
●
/
●
●
●
24
25 2nd
acceleration/deceleration
●
/
●
●
●
26
27 3rd
acceleration/deceleration
●
/
●
●
●
28
29
2nd V/F control mode switching
●
/
●
●
●
32
33
2nd stall prevention level
●
/
●
●
●
36
37
PID control prohibition
●
/
●
●
●
46
47
External thermal error input
●
/
●
●
●
48
49
Forced local from communication
●
/
●
●
●
50
51
Operation hold (hold of 3-wire operation)
●
/
●
●
●
52
53
PID integral/differential clear
●
/
●
●
●
54
55
PID characteristics switching
●
/
●
●
●
56
57
Forced run operation
●
/
●
●
●
58
59
Fire speed operation
●
/
●
●
●
60
61 Acceleration/deceleration
suspend
signal
●
/
●
●
●
62
63
Power failure synchronized signal
●
/
●
●
●
64
65
My function-S trigger signal
●
/
●
●
●
74
75
Integrating wattmeter(kWh) display clear
●
/
●
●
●
76
77
Trace back trigger signal
●
/
●
●
●
78
79
Light-load high-speed operation
prohibitive signal
●
/
●
●
●
80
81
Holding of RY-RC terminal output
●
/
●
●
●
82
83
Holding of OUT terminal output
●
/
●
●
●
88
89 Frequency
UP
●
/
●
●
●
90
91 Frequency
DOWN
●
/
●
●
●
92
93
Clear frequency UP/DOWN
●
/
●
●
●
96
97 Coast
stop
command
●
/
●
●
●
98
99 Forward/reverse
selection
●
/
●
●
●
100
101 Run/Stop
command
●
/
●
●
●
104
105
Frequency setting mode forced switching
●
/
●
●
●
106
107
Frequency setting mode terminal block
●
/
●
●
●
108
109
Command mode terminal block
●
/
●
●
●
110
111 Parameter
editing
permission
●
/
●
●
●
120
121
Fast stop command 1
●
/
●
●
●
122
123
Fast stop command 2
●
/
●
●
●
134
135
Traverse permission signal
●
/
●
●
●
136
137
Low voltage operation signal
●
/
●
●
●
140
141
Forward
deceleration
●
/
●
●
●
142
143
Forward
stop
●
/
●
●
●
144
145
Reverse
deceleration
●
/
●
●
●
146
147
Reverse
stop
●
/
●
●
●
152
153
No.2 motor switching
(AD2 + VF2 + OCS2)
●
/
●
●
●
200
201
Parameter editing prohibition
●
/
●
●
●
202
203
Parameter reading prohibition
●
/
●
●
●
* This function is not dependent on
cmod
.