background image

Содержание Carrier TCB-AX21UL

Страница 1: ...X21 UL Wireless remote controller Generic model name and signal receiving unit TCB AX21 UL WX TA01U ES Wireless remote controller model name zesmsA ca m Wireless remote controller Signal receiving WX TA01 UES unit Owner s Manual Remote controller for air conditioner Split type 1 Manuel du proprietaire Telecommande pour climatiseur Type split 19 ...

Страница 2: ...on manual from constructor or dealer Request to constructor or dealer Please clearly explain the contents of the Owner s manual and hand over it Contents 1 PRECAUTIONS FOR SAFETY 2 2 PART NAMES AND FUNCTIONS 4 3 CORRECT USAGE 9 4 TIMER OPERATION 10 5 SLIDE SWITCH 11 6 HOW TO INSERT THE BATTERIES 12 7 HOW TO HANDLE THE REMOTE CONTROLLER 13 8 HOW TO USE THE REMOTE CONTROLLER CORRECTLY 14 9 ADDRESS 1...

Страница 3: ...he remote controller Do not spill juice water or any kind of liquid It may cause malfunction electric shock or fire etc When you are aware of any error with the air conditioner smells like something burning etc immediately turn off the circuit breaker to stop the air conditioner and make contact with the dealer If the air conditioner is continuously operated with an error it may cause malfunction ...

Страница 4: ...er the direct sunlight and close to any heat source It may cause malfunction The fluorescent tamp with rapid start system or inverter system may disturb the signal reception For details contact with the dealer of the air conditioner you have purchased CAUTIONS ABOUT OPERATION Do not drop or apply strong shock to the air conditioner It may cause malfunction of the remote controller Use batteries th...

Страница 5: ...peripheral temperature is sensed when the sensor button is pushed to remote controller side 3 LCD The operation mode is displayed 4 ON OFF button Pushing this button starts and pushing again stops the unit 5 Mode button Selects desired operation mode 6 Fan speed button 7 Timer Set button Use to setup the timer See page 10 8 ACL button This button is used after replacement of battery or selection o...

Страница 6: ... the set point Set the desired set point by pushing _ _ or _ Filter button No function Swing Air direction button No function Address button See page 14 Ventilation button Use this when a ventilation fan or other unit purchased on the market has been connected Sensor button This button is used when selecting the temp sensor at the remote controller side At the shipment from the factory this button...

Страница 7: ...K in 17 page 4 lamp This lamp illuminates when unit is on 5 _ lamp This lamp illuminates while the timer is reserved 6 _ lamp In heatingoperation this lamp illuminates in the following cases The operation has started The temp controller has worked The unit is under defrost operation This lamp flashes while a trouble occurs 7 lamp This lamp illuminates to reamind to clean the air filter Z_ CAUTION ...

Страница 8: ...ation mode is displayed 3 Fan speed display The selected fan speed is displayed AUTO N _ HIGH _ NED _ LOW K 4 Ventilation display This appears while the ventilation fan is operating 5 Remote control sensor display This appears when the remote control sensor is used 6 Set up temperature display The selected set point is displayed 7 8 9 10 Louver position display SWING display Displayed during up do...

Страница 9: ... Use this button after battery exchange 5 Setup Temperature button Adjusts the set point Set the desired set point by pushing _ or T _b 6 ON OFF button When the button is pushed operation starts and it stops by pushing the button again When the operation stops the operation lamp and all displays disappear 7 Filter button No function OPTION Remote controller sensor Usually the TEMP sensor of the in...

Страница 10: ...is not comfortably heated with FAN X select FAN XJ_ or HI Although they are displayed the function may not be provided according to the used indoor unit Fan speed is constant When the unit cannot be stopped by the normal operation Turn off the circuit breaker and then contact the shop which you purchased the unit Automatic cool heat When all indoor units in the identical refrigerant system are con...

Страница 11: ... 5 hours 30 minutes each time you push _ The minimum setup time is 0 5 hours Timer display Each time you push Timer _ the timer display changes as follows _ _SQIZ_q 8B 881 No dis_play Use Examples Setting OFF timer Example To stop operation in 30 minutes 1 Push Timer F _ I and the time flash on the display 2 Set the time to 0 5 with TIME _ or IT 3 Push _ and _ go on timer Setting repeat timer Exam...

Страница 12: ...n occurs by other settings View with the cover removed ACL button 1 Louver display switch 2 2 Louver display of the remote controller Slide switch position SKN Set the slide switch to S Otherwise the air direction adjustment and louver display are disabled Operation mode switch Operation mode display of the remote controller Slide switch position g6 X AHC Before using the air conditioner check tha...

Страница 13: ...ething tipped and attach the cover Replace the batteries when the display section of the remote controller is difficult to be read or when the signal cannot be sent if you are not close to the signal receiving unit The standard replacement time of the alkali batteries is approx one year Use the same type of new batteries for replacing two batteries In case when you do not the remote controller for...

Страница 14: ...remote controller Do not put the remote controller on the place exposed to the direct sunlight or air from the air conditioner or near the stove etc Do not drop throw or clean with water the remote controller The signal may be accepted in a room where the electronic instantaneous ON type or inverter type florescent light is set For details contact the shop which you purchased the air conditioner T...

Страница 15: ...ber of the remote controller address Max 6 indoor units can be controlled by the corresponding remote controller individually For the seventh indoor unit onwards address setting is necessary from wired remote controller The address switch for receiving the signal is prepared to the signal receiving unit and the address switch for sending the signal is prepared to the remote controller For details ...

Страница 16: ... 3 When pushing _ the address display goes on and is displayed for 5 seconds If the address matches with the address switch of the operation part the buzzer sounds Display of remote controller address Address switch position of signal receiving unit Address Rl J LL Address switch of signal receiving unit can be set any position Address Address t t 2 123 123 45_ _ _56 _ J The address switch is insi...

Страница 17: ... 1 Start Push temporary operation If starting theoperationwhen the room temperature is 75 F 24 C orhigher the mode enters COOL mode If starting the operationwhen the roomtemperature is 75 F 24 C or lower the mode enters HEAT mode 2 stop Push temporary operation once more _ CAUTION The ON switch of the test run and the ON switch of the test are used for the test run mode in the installation time Do...

Страница 18: ...tch is Is the power supply of the power switch Turn on the power supply switch if not turned on Fuse Contact the shop which you purchased the air conditioner Is not the mode ON timer Delete the timer operation Is not ALL OFF of Signal Receiving Unit Set the switch to Normal position and selected stop the operation Is not the battery of the remote controller Replace the battery expired Is not the s...

Страница 19: ...t Q A protective device of the indoor unit works G A protective device of the outdoor unit works Q _ A trouble occurred on the temperature sensor 0 Q The compressor of the outdoor unit is protected _ Q _ _ The test run is performed Turn off the Trial ON switch Please check the above items If the trouble yet remains stop the operation turn off the power switch and then notify the shop which you pur...

Страница 20: ...85464609013000 EH99677701 ...

Отзывы: