– 14 –
Cooling
Surface temp. of heat
exchanger interchang-
ing pipe (°C)
Ambient temp.
conditions DB/WB
(°C)
Tr
2
49.0
60.0
33.0
Outdoor
35/24
43/26
21/15
Indoor
27/19
32/23
21/15
Tr
1
9.0
15.0
0.5
Standard
High temperature
Low temperature
6. REFRIGERANT CYCLE DIAGRAM
RAS-07EK/RAS-07EA
RAS-09EK/RAS-09EA
Note:
•
Measure the heat exchanger temperature at the center of U-bend (By means of thermistor thermometer.)
Fig. 6-1
Table 6-1
50Hz
Standard pressure
P
1
(kg/cm
2
G)
5.7
6.5
3/5
Capillary tube
/ 1.5x1500
0.37m
/ 9.52( / 3/8 in)
Mark( )means check points of Gas Leak
TI
T2
Pressure check
(Gauge port)
Air purge here
Auxiliary pipe
Compressor
Condenser
Dryer
Indoor unit
Evaporator
Cross flow fan
Optional piping kits
RB-P31BEF1 (3m)
RB-P51BEF1 (5m)
RB-P71BEF1 (7m)
Propeller fan
Outdoor unit
PH70T1-4C
P1
Gas container
connection
(Reinstall.etc.)
0.47m
/ 6.35( / 1/4 in)
Auxiliary pipe
Max length 10m
Allowable height 5m
Compressor
Refrigerant
rated volume
Unit
R-22 0.50kg
07EA
PH94T1-4C
R-22 0.57kg
09EA
Accum-tank