FILTER SET REPLACEMENT

Filter Replacement Time

Replace the filter regularly as its air purifying effect drops if it is used for a long period of time.

Standard replacement time is approximately once every 5 year [based on JEM standard (Standards of
the Japan Electrical Manufacturer’s Association)]. Replacement time, however, varies depending on how
and where the filter is used.

Make sure to replace the filter with a new one if the “FILTER REPLACE” indicator
lights up.

Even if the “FILTER REPLACE” indicator does not light up, replace the filter with
a new one of you feel any odor from the filter or when there is a difficulty in
eliminating dirt, odor and/or smell.

How to Replace

Disconnect the cable from the plug outlet.

Bring out the filter unit after detaching the panel.

Attached to the new filter unit.

After replacing the filter unit, plug the cable, press the
FILTER RESET button, and make sure the FILTER
REPLACE indicator turns off.

Attach the panel.

ATTENTION

When the REPLACE FILTER indicator turns off,
a microcomputer starts counting for the timing to
replace the filter.

Do not press the reset button except when the filter
unit has been replaced. It makes difficult to count
accurately.

Filter Unit

Purchase the filter unit at the shop from which you bought this product with designating the model.

NOTICE

The filter set connot be reused even if it is
washed.

Classify the type of waste on filter set, in order
to discard.

FILTER RESET button

Содержание CAF-G3A

Страница 1: ...NUAL MODEL CAF G3I CAF G3A Thank you for purchasing a Toshiba air purifier Please read and understand this manual thoroughly in order to use this product safely Please keep this manual at hand for quick reference after you have read it ...

Страница 2: ...ssibility where if you use this product in an improper way you will die or be seriously injured This signal indicates the possibility where if you use in an improper way you will be injured or property damage will be caused CAUTION WARNING Symbol Meaning of the Symbol Indicates prohibitions which are supposed not to do Objective prohibited act appears in or near with a picture or texts The left ex...

Страница 3: ...and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety CAUTION When you do not use for a long period disconnect the cable from the plug outlet Degraded insulation may cause a fire Disconnect the Cable Do not spray flammable gas such as hair spray or thinner It may cause a fire and explosion PROHIBITED Do not wip...

Страница 4: ... Dirt sensor odor smoke Part around the sensor gets warm both in operation and stop but this is not broken Reset button This button should be pressed after changing the filter unit Pre Filter Deodorant Filter Can be washable Remove pet smell smoking smell and unpleasant smells ...

Страница 5: ... kg Maximum Floor Area 33 m2 Length of Power Cable 2 m Accessories Filter unit in the main body 1 piece Deodorant filter in the main body 1 piece Pre Filter 1 piece Grip handle Use this handle to carry the product Model indication Filter unit High performance filter It is high performance filter as to eliminate 96 00 of small particulates of 0 3 micrometers Anti bacteria filter It is anti bacteria...

Страница 6: ...nse of smell differs in individuals odor may be smelled even after the indication of the AIR MONITOR turns to be CLEAN Replace filter indicator This shows the time to replace filter unit Air Volume monitor lamp The amount of air volume is shown here by illuminating lamps in 3 scales when this product is in operattion Memorizing Clean Air Plug the cable while the air is clean A green lamp far to th...

Страница 7: ...s automatically depending on the dirtiness The product does not stop and keep running with low even after the air becomes clean and keeps the air clean When the air is clean When the air is not clean Runs with LOW Runs with up to the maximum air volume of HIGH Air volume select button Each time you press the button air volume changes in the following order On Off button Each time you press the but...

Страница 8: ...2 Bring the filter unit and deodorant filter out of the plastic bag and mount it to the body Remove the plastic bag completely Pay attention to the orientation of the filter It would be convenient to fill in the mounting month 3 Bring the Pre Filter mount it to the body Flow of air Do not use in the kitchen Sensor will be tarnished with oily smoke and the sensitivity of the sensor will become unst...

Страница 9: ...ty in eliminating dirt odor and or smell How to Replace Disconnect the cable from the plug outlet Bring out the filter unit after detaching the panel Attached to the new filter unit After replacing the filter unit plug the cable press the FILTER RESET button and make sure the FILTER REPLACE indicator turns off Attach the panel ATTENTION When the REPLACE FILTER indicator turns off a microcomputer s...

Страница 10: ...careful not to tear the surface of the filter by pushing the nozzle of a vacuum cleaner Use the vacuum cleaner with a low power Sensor Air Intake Air Intake of the Panel and Filter Unit Clean approximately every 2 weeks Air Intake of the Panel Vacuum with a nozzle of a vacuum cleaner Deodorant filter Fill water and mix the neutral detergent for kitchen use Do not use other detergent except the neu...

Страница 11: ...11 ...

Страница 12: ...AFNL10000000086 ...

Отзывы: