background image

7

A

B

FG

U1

U2

TCC-LINK

RS-485

SW6

ON

1

2

U2 U1

U4 U3

U2 U1

U4 U3

U4 U3

ON

1

1

2

SW5

SW6

ON

1

2

ON

1

2

SW5

SW1

ADDRESS

8

SW1

ADDRESS

A

B

L

N

L

N

L

N

L

N

FG

U1

U2

TCC-LINK

RS-485

DI 8

DI 7

DI 6

DI 5

DI 4

DI 3

DI 2

DI 1

1

SW1

ADDRESS

RS-485

RS-485

+12V

GND

DO 4

DO 3

DO 2

DO 1

DI 8

DI 7

DI 6

DI 5

DI 4

DI 3

DI 2

DI 1

4

SW1

ADDRESS

U2 U1

U2 U1

U2 U1

U2 U1

U4 U3

U2 U1

U4 U3

U4 U3

U2 U1

U2 U1

U2 U1

B

A

B

A

Customer's PC

Red

Orange

Crimp 3 wires with

a closed end wire joint.

Red/Orange

Bro

wn/Y

ello

w

DIGITAL I/O
INTERFACE

ENERGY
MONITORING
INTERFACE

Power meter 1
Power meter 2
Power meter 3
Power meter 4
Power meter 5
Power meter 6
Power meter 7
Power meter 8

Input contact 1
Input contact 2
Input contact 3
Input contact 4
Input contact 5
Input contact 6
Input contact 7
Input contact 8

Load 1
Load 2
Load 3
Load 4

TCS-NET RELAY
INTERFACE

RS-485
TERMINATOR

Outdoor

unit

Indoor unit

Indoor unit

Remote

controller

Outdoor

unit

Indoor unit

Remote

controller

Central remote

controller

A

B

A

P

o

w

er supply

P

o

w

er supply

P

o

w

er supply

Switching HUB

TOUCH SCREEN

CONTROLLER

Caution:

RS-485 cab

le has polar

ity

.

If incorrectly connected, it

does not work.

Y

e

llo

w

Brown

P

o

w

er supply

TCS-NET RELAY
INTERFACE

TCC-LINK
TERMINATOR

TCC-LINK
TERMINATOR

RS-485
TERMINATOR

Outdoor

unit

Indoor unit

Indoor unit

Remote

controller

Outdoor

unit

Indoor unit

Remote

controller

Central remote

controller

B

Connection of Power cables/Earth wires/

2

Signal wires

 (continued)

The example of the system wiring connection is shown below.

Terminator Resistor Setting

RS-485 terminator resistor

The terminator resistors of RS-485 are set at both ends of communication cable. The RS-485
terminator resistor (at one end) of the Touch Screen Controller is set at shipment. No setting is needed.

The setting of the Touch Screen Controller is done at shipment. No setting is required.

Содержание BMS-TP0641ACE

Страница 1: ...rol System Thank you very much for purchasing the TOSHIBA Touch Screen Controller Please read this manual carefully beforehand for proper installation of the controller CONTENTS Precautions for Safety 1 Introduction 2 Before Installation 3 1 Installation 3 2 Connection of Power cables Earth wires Signal wires 5 3 Trial Operation 8 ...

Страница 2: ...odify the unit Any modification may cause a malfunction resulting in overheating or fire WARNING Upon customer s approval install the Touch Screen Controller at a place which satisfies the following conditions Place where the Touch Screen Controller can be installed securely Place which can reserve a sufficient service space for safe maintenance or check Place where CF Compact Flash card can be re...

Страница 3: ... 240 VAC 50 60Hz 50VA 0 C to 50 C 20 to 85 RH no condensation 10 C to 60 C 256 H 316 W 54 D mm 3 5kg Air conditioning control Power distribution Indoor units connected BMS TP0641ACE BMS TP0641PWE BMS TP5121ACE BMS TP5121PWE Max 64 units Max 64 units Max 512 units Max 512 units ExternalView 249 95 75 91 75 256 19 30 16 54 5 49 242 99 3 75 82 5 302 55 5 48 70 75 316 Function switch F1 F2 F3 PCI expa...

Страница 4: ...pact flash from coming out For card cover For connecting controller and TCS NET Relay Interface This manual Use the following materials to connect the signal lines and power lines procured on site Line For RS 485 For digital Input Output connection For Power Type Wire size Length Type Wire size Length Type Wire size Description 2 core shield wire 1 25mm2 500m max total length 2 core wire 0 3mm2 10...

Страница 5: ... 1 0 243 1 0 R1 or less mm Panel thickness 1 6 7 mm REQUIREMENT Use a panel procured on site of thickness 1 6 7 mm 2 Desk Top Installation using the CONTEC stand procured on site For reference Display stand not supplied with the controller Use the CONTEC stand model IPC SND 03 For details of the stand visit the CONTEC web site Europe http www contec europe com China http www contec sh cn The angle...

Страница 6: ...r details of the connection refer to I O port connection on next page Connect firmly the power cable to the power input terminal COM2 RS 485 TCS NET relay interface Power supply Connect the attached RS 485 cable to COM2 Ethernet To customer s PC Length of stripped power cable Length of stripped digital Input Output connector wire CAUTION Ensure to connect the breaker to the primary side of power C...

Страница 7: ...er insulation 3 3k ohm Open collector 3 Max 100mA per 1 output Less than 30V DC Input type Number of input Input resistance Output type Number of output Output current Output voltage 1 The example of input circuit is shown below It is electrically insulated by the photo coupler 2 The example of output circuit is shown below It is electrically insulated by the photo coupler 10 k ohm 3 k ohm 1 2 W P...

Страница 8: ...LAY INTERFACE RS 485 TERMINATOR Outdoor unit Indoor unit Indoor unit Remote controller Outdoor unit Indoor unit Remote controller Central remote controller A B A Power supply Power supply Power supply Switching HUB TOUCH SCREEN CONTROLLER Caution RS 485 cable has polarity If incorrectly connected it does not work Yellow Brown Power supply TCS NET RELAY INTERFACE TCC LINK TERMINATOR TCC LINK TERMIN...

Страница 9: ...tion of Communication with Each Interface When the communication with the interface listed on the setting file is disconnected the communication error is displayed on the Touch Screen Controller Press the Alarm List button to confirm whether the communication error occurs or not Communication error judging time Approx 15 minutes The suspected causes of the communication error will be as follows Th...

Страница 10: ...EH99852501 ...

Отзывы: