background image

 

4

 

NOTICE FOR THE CUSTOMERS IN THE UNITED KINGDOM 

 

A moulded plug complying with BS 1363 is fitted to this equipment for your safety 
and convenience.  

Should the fuse in the plug supplied need to be replaced, a 5 AMP fuse 
approved by ASTA or BSI to BS 1362, (i.e., marked with 

 or 

 mark) must 

be used. 

If the plug supplied with this equipment has a detachable fuse cover, be sure to attach the 
fuse cover after you change the fuse. Never use the plug without the fuse cover. If you 
should lose the fuse cover, please contact your nearest TOSHIBA TEC service 
representative.  

 
 
 
 
 
 
 
 

Others 

 

•  The model name plate indicating the operating voltage, power consumption, etc. 

is located on the bottom of the unit.  

•  Unplug the unit from the wall outlet if it will not be used for an extended period of 

time. To disconnect the cord (mains lead), pull it out by the plug. Never pull the 
cord itself.  

• Do not operate the unit with a damaged cord or if it has been dropped or damaged.  
•  Be sure that nothing metallic comes into contact with the metal parts of the unit or 

connecting plate. If it does, a short may occur and the unit may be damaged.  

•  Always keep the metal contacts clean.  
•  Do not disassemble or convert the unit.  
•  Do not apply mechanical shock or drop the unit.  
•  The unit may become warm whilst in use, this is perfectly normal.  
•  Keep the unit away from AM receivers, because it will disturb AM reception.  
•  Do not place the unit in a location where it is:  

•  Temperatures out of the specification 

•  Dusty or dirty  
•  Very humid  
• Vibrating  

If any difficulty should arise, unplug the unit and contact your Authorised TOSHIBA 
TEC representative. 
 

WARNING!

1. To prevent fire or shock hazard, do not expose the unit to rain or moisture. 
2. To avoid electrical shock, do not open the cover. 
3. Refer servicing to qualified personnel only.

 

4. For indoor use only. 

 

5

 

 

Before using this unit:

 

Please follow the instructions below to use the B-EP800-AC-QM-R correctly.  
•  The B-EP800-AC-QM-R is an AC adapter designed for charging the battery pack 

loaded in the B-EP2DL/B-EP4DL series portable printers, not for directly supplying 
the power to the B-EP2DL/B-EP4DL series portable printers. 

  This product and the AC adapter supplied with the B-EP800-CHG-QM-R Battery 

Charger are the same product.   

•  DO NOT connect this AC adapter to any devices other than the B-EP2DL/B-

EP4DL series portable printer.  We assume no responsibility for any results 
arising from a connection to other devices. 

•  Before connecting this AC adapter to the printer, please make sure that the 

battery pack is in the printer.  We are not responsible for any results due to a 
failure to do so. 

 

 

Connecting the AC Adapter to the Printer

 

When charging the battery pack loaded in the B-EP2DL/B-EP4DL series portable 

printer, use the following procedure to connect the AC adapter to the printer.  

For how to check the charge status, please refer to the Owner’s Manual of the B-

EP2DL/B-EP4DL series portable printer.  

 

1.   Make sure that the battery pack is in the printer.  

2.   Connect the AC adapter to the DCIN connector of the printer.  
3.   Connect the power cord to an AC outlet.  
4.  When the AC adapter is plugged in, the external power source symbol (

 is 

displayed on the printer’s LCD, and charging starts.  Whether the battery charge 
is required or not is automatically determined by the printer.

 

  

5.  When the charging is completed, unplug the power cord from the AC outlet and 

disconnect the AC adapter from the printer.  

 

NOTE: 

Charging time may differ 
depending on the condition of the 
battery pack or the operating 
temperature.

 

 

 

 

 

 

 

 

 

AC Adapter

 

Portable Printer

 

Plug

 

DCIN Connector

 

Power Cord

 

Power Plug

 

AC outlet

 

 

6

 

 

Troubleshooting

 

If you have any problems while using this product, please check the following point first.   

If a problem cannot be solved by taking actions described below, unplug the AC adapter and 

contact the dealer or an authorized TOSHIBA TEC service representative for assistance.

 

Symptom 

Cause and resolution 

The power is not supplied even if the 

power cord is connected to an AC 

outlet. 
(

 is not displayed.) 

 The AC adapter is not connected to the printer completely.  

Firmly connect the AC adapter to the printer.  

 The power cord is not connected to the AC adapter completely. 

Firmly connect the power cord to the AC 
adapter.  

 The power cord is not connected to the AC outlet completely.  

Firmly connect the power cord to the AC outlet.  

 A power failure 

Please wait until the power is recovered.  

 Power is not supplied to the AC outlet.  

Test with other electric appliances.  If the power is not 

supplied to the AC outlet, please consult the nearest power 

company.  

 The fuse or breaker of the building has blown out.  

 Check the fuse and the breaker.  

 The printer is not in stand-by.  

The external power source symbol is not displayed while the 

printer is not in the stand-by state. 

 

The CHARGE lamp does not light up. 

 The battery pack is not loaded in the printer.  

Load a battery pack in the printer.  

 The battery pack loaded in the printer has been fully charged.  

A fully charged battery pack is not charged, so  
the CHARGE lamp does not light up.  

 The ambient temperature or the battery pack temperature does 

not fall within the operable temperature range.  

Charge the battery pack within 0ºC to 40ºC.  A  
battery charge may not be started outside this 
range. 

 

 

Specifications

 

Type: 

   B-EP800-AC-QM-R 

(Model: 

0225A1950)

 

Input voltage:   

 

100 to 240V AC, 50/60 Hz

 

Output voltage:    DC19V, 

2.63A

 

Application:  

 

TOSHIBA 

Portable Printer B-EP2DL/ B-EP4DL Series

 

Operating temperature:  

0°C to 40°C (32°F to 104°F)

 

Operating humidity:  

 

20 to 80% (No condensation)

 

Storage temperature:   

-20°C to 70°C (-4°F to 158°F)

 

Storage humidity:  

 

10 to 90% (No condensation)

 

Dimensions:    

 

98 x 42 x 29.2mm (L/W/H)

 

(3.86 x 1.65 x 1.15 inches) (Excluding the projecting parts)

 

Weight: 

   250g 

(8.8 

oz)

 

Accessories:    

 

Owner’s Manual x 1  

 

NOTE:

 Design and specifications are subject to change without notice.

 

 

7

 

 

When purchasing the power cord: 

Since the power cord set is not enclosed in this unit, please purchase an approved one that meets the following 
standard from your authorized TOSHIBA TEC representative.  

(As of August 2008) 

Country Agency 

Certification 

mark 

Country 

Agency  Certification mark 

Country 

Agency 

Certification mark 

Australia SAA 

Germany VDE 

 

Sweden SEMKKO 

 

Austria OVE 

 

Ireland NSAI 

Switzerland SEV 

Belgium CEBEC 

 

Italy IMQ 

 

UK ASTA 

 

Canada CSA 

 

Japan METI 

 

UK BSI 

 

Denmark DEMKO 

 

Netherlands KEMA 

 

U.S.A. UL 

 

Finland FEI 

 

Norway NEMKO 

 

Europe HAR 

 

France UTE 

 

Spain AEE 

 

China CCC 

 

 

Power Cord Instruction 

1.  For use with 100 – 125 Vac mains power supply, please select a power cord rated Min. 125V, 10A. 
2.  For use with 200 – 240 Vac mains power supply, please select a power cord rated Min. 250V. 
3.  Please select a power cord with the length of 2m or less. 
4.  The power cord plug connected to the AC adapter must be able to be inserted to an ICE-320-C6 inlet.  Refer to 

the following figure for the shape. 

 
 
 

Country/Region North 

America 

Europe 

United 

Kingdom 

Australia China 

Power Cord 

Rated (Min.) 
Type 
 
Conductor size 
(Min.) 

 
125V, 10A 
SVT 
 
No. 3/18AWG 

 
250V 
H05VV-F 
 
3 x 0.75 mm

2

 

 
250V 
H05VV-F 
 
3 x 0.75 mm

2

 

 
250V 
AS3191 approved, 

Light or Ordinary Duty type 

3 x 0.75 mm

2

 

 
250V 
GB5023 
 
3 x 0.75 mm

2

 

Plug Configuration 
(locally approved 
type) 
 
 
Rated (Min.) 

 

 

 

 

 

125V, 10A 

 

 

 

 

 

250V, 10A 

 

 

 

 

 

250V, *1 

 

 

 

 

 

250V, *1 

 

 

 

 

 

250V, *1 

*1:  At least, 125% of the rated current of the product.

 

 