17
–
FILE NO. SVM-04007-(1)
4-5. Outdoor Unit (RAS-24UA-ES3, RAS-24UA-AS3)
No.
Parts name
Type
Specifications
Output (Rated) 2200W, 2poles, 1 phase, 220
−
240V, 50Hz
1
Compressor
5JS315DAB
Winding resistance (
Ω
)
Red-Black
White-Black
(at 20
°
C)
0.83
2.257
Output (Rated) 65W, 6poles, 1 phase, 220
−
240V, 50Hz
2
Fan motor (for outdoor)
KFG6-71SB5P-T
Winding resistance (
Ω
)
Red-Black
White-Black
(at 20
°
C)
64.4
127.4
3
Running capacitor
451355KQ
AC 450V, 3.5
µ
F
(for fan motor)
4
Running capacitor
371456JCR
AC 370V, 45
µ
F
(for compressor)
5
Starting capacitor
(for compressor)
(RAS-24UA-AS3)
371456JCR
AC 370V, 45
µ
F
6 Magnetic contactor
CLK-35J
220
−
240V, 50Hz
7 Electric starter
ZPR0YCE101A500 AC 500V, 100
Ω
4-6. Outdoor Unit (RAS-18UA-ES3, RAS-18UA-AS3)
No.
Parts name
Type
Specifications
Output (Rated) 1500W, 2poles, 1 phase, 220
−
240V, 50Hz
1
Compressor
5KS225DAA Winding resistance (
Ω
)
Red-Black
White-Black
(
at 20°C )
1. 632
2.457
Output (Rated) 42W, 6poles, 1 phase, 220
−
240V, 50Hz
2
Fan motor (for outdoor) HF-240-42B-1
Winding resistance (
Ω
)
Red-Black
White-Black
(at 20
°
C)
176.2
290.5
3
Running capacitor
451205KQ
AC 450V, 2
µ
F
(for fan motor)
4
Running capacitor
371456JCR AC 370V, 45
µ
F
(for compressor)
5
Magnetic contactor
CLK-26J
220
−
240V, 50Hz