background image

Industrial Division / Houston Motor Plant

 

SHEET NO.

 

3 of 3

 

 

ISSUED

 

01/24/96

 

Motor Operation Procedure

SUPERSEDES

 

NEW

 

 

Fig.  3

 

 

 

TYPE OF SERVICE 

 

 

 SYNC. 

RPM 

RANGE 

FRAME SIZE 

STANDARD 

DUTY 

SEVERE 

DUTY 

VERY SEVERE 

DUTY 

 

 3600 

1800 ~ 900 

143T-256T 
143T-256T 

8 Mos. 

30 Mos. 

4 Mos. 

12 Mos. 

1 Mo. 

4 Mos. 

 

 Bearing 

Size 

6205/6206 

6207/6208/6305 

6306 

6308/6309 

Periodic Grease Amount 

3 Grams 
5 Grams 

10 Grams 
20 Grams 

 

 3600 

1800 ~ 900 

284T-365T 
284T-365T 

8 Mos. 

24 Mos. 

4 Mos. 

12 Mos. 

1 Mo. 

4 Mos. 

 

 Bearing 

Size 

6211 
6309 

6310/6312 

6314 

Periodic Grease Amount 

10 Grams 
20 Grams 
30 Grams 
50 Grams 

 

 3600 

1800 ~ 900 

404T-447T 
404T-447T 

8 Mos. 

18 Mos. 

4 Mos. 
8 Mos. 

1 Mo. 

3 Mos. 

 

 Bearing 

Size 

6216 

6313/NU317 

NU318/NU320 

6317/6318 

6320/6322/6324 

NU322/NU324 

NU328/NU2228 

Periodic Grease Amount 

20 Grams 
30 Grams 
50 Grams 
80 Grams 
80 Grams 
80 Grams 

100 Grams 

 

 

 

 

 

 

 

 

NOTES:

 

1. 

When relubricating roller bearings divide the monthly service time by two. 

2. 

See Fig. 2 for definitions of Service Conditions. 

3. 

Gram quantity when using a typical low pressure hand grease gun equals 

 

(4 pumps = 5 grams) 

 

6. 

RECOMMENDED GREASES FOR SPECIAL APPLICATIONS

 

 
 

The following greases are recommended for special applicaitons only and should be used only for motors 
specifically built for such conditions.

 

 
 

Minimum Ambient Temp. -60°C

 

 

 

Beacon 325 

Exxon Corp. 

 

 

Maximum Ambient Temp. 90°C 

 

 

DOW Corning 44 
Exxon Unirex S2 

DOW Corning Corp. 
Exxon Corp. 

 

 
WARNING:  In general it is not recommend to mix greases of different brands.  The mixing of different types of thickeners may destroy the 
composition  and physical properties of the grease.  In the event that a different grease is required by the end user, the following steps can 
be taken.  Using the instructions for lubrication, open grease outlet and purge the system as much as possible of the old or unwanted 
grease.  Repeat this same operation after 1 week of service.  Consult TOSHIBA/HOUSTON Engineering for further recommendations on 
grease compatibility.

 

 

 