54
H7 ASD Operation Manual
Motor #1 Torque Boost
Program
⇒
Fundamental Parameters
⇒
Motor Set #1
The Motor #1 Torque Boost function is used to increase the low frequency
torque for high-inertia loads by increasing the output voltage at frequencies
below ½ of the #1 Base Frequency (
) setting.
The value programmed as a boost percentage establishes an output voltage vs.
output frequency relationship to be used to start the motor or to provide
smoother operation.
Note: Setting an excessive Torque Boost level may cause nuisance tripping and
mechanical stress to loads.
Direct Access Number — F016
Parameter Type — Numerical
Factory Default — (drive dependent)
Changeable During Run — Yes
Minimum — 0.0
Maximum — 30.0
Units — %
Soft Stall
Program
⇒
Protection Parameters
⇒
Overload
This parameter Enables/Disables the Soft Stall function. When enabled, the
Soft Stall function reduces the output frequency of the ASD when the current
requirements of the motor exceed the Electronic Thermal Protection #1
setting (
); thus, reducing the output current. If the current drops below the
motor overload protection level setting within a specified time, the output of the
ASD will accelerate to the programmed frequency setpoint. If not, a trip will be
incurred.
The Soft Stall feature is available when the (Program
⇒
Protection Parameters
⇒ Overload
⇒
Motor Overload Trip Enable/Disable
parameter is enabled
only.
Soft Stall is highly effective in preventing motor overload trips when used on
fans, blowers, pumps, and other centrifugal loads which require less torque at
lower frequencies.
Note: The Soft Stall setting may affect acceleration times and patterns.
Direct Access Number — F017
Parameter Type — Check Box
Factory Default — Not Selected
Changeable During Run — No
www
. ElectricalPartManuals
. com
Содержание Adjustable Speed Drive H7 Series
Страница 198: ...H7 ASD Operation Manual Appendix A 191 Figure 23 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Страница 199: ...192 Appendix A H7 ASD Operation Manual Figure 24 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Страница 201: ...194 Appendix A H7 ASD Operation Manual Figure 26 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...