![Toshiba 50L2331D Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/toshiba/50l2331d/50l2331d_service-manual_428425024.webp)
(1/1)
AFTER MAIN PCB REPLACEMENT
The following setting must be checked after PCB replacement to make sure, that PCB
setting corresponds to the panel type:
1. Enter Factory Menu:
-
MENU
-
Applications
-
Sleep Timer + “2766”
2. Go to page 3 and select the proper panel type (take care of the full panel name, not only
panel vendor name).
Panel type can be found on the panel serial number sticker.
3. Press EXIT to leave the factory mode (please make sure you have selected the proper
panel type, before you press EXIT !).
4. If the proper panel type was set, TV will come up with proper picture after TV restart.
PLEASE TAKE CARE: set may come up with NO PICTURE at all when wrong panel was
selected and it will be very difficult/impossible to adjust the proper settings afterwards.