– 10 –
GENERAL ADJUSTMENTS
SPECIFIC INFORMATIONS
8. SELF DIAGNOSTIC FUNCTION
1) Press “9” button on Remote Control during display of adjustment menu in the service mode.
The diagnosis will begin to check if interface among IC’s are executed properly.
2) During diagnosis, the following displays are shown.
SELF CHECK
NO. 23 * * * * * *
POWER : 000
BUS LINE : OK
BUS CONT : OK
BLOCK : UV V1 V2
or QV01 QV01S
SYNC
���
���
���
���
���
���
Part number of microprocessor (QA01)
���
Operation number of protection circuit (current limiter) . . . . “000” is normal.
���
BUS line check
“OK” ................... Normal
“NG” ................... SCL-GND
or SAD-GND short circuit
���
BUS line ACK (acknowledge) check
“OK” ..................... Normal
Display of Location Number . . . . NG
(Display example)
“QA02 NG”, “H001 NG”, “Q501 NG” etc.
Note: The indication of failure place is only one place though failure places are plural. When
repair of a failure place finishes, the next failure place is indicated. (The order of priority of
indication is left side.)
���
Sync. signal check
Green display ..... Normal
Cyan display ...... No check
Red display ........ NG
UV ........... TV mode
V1 ............ VIDEO 1 mode
V2 ............ VIDEO 2 mode
*
The item marked with
are not usable to display in the SELF DIAGNOSTIC FUNCTION for some model.
Содержание 27AF41
Страница 21: ... 21 GENERAL ADJUSTMENTS SPECIFIC INFORMATIONS QZ01 DIG Comb ZY01 PIP Module CIRCUIT BLOCK DIAGRAM ...
Страница 32: ... 32 SPECIFIC INFORMATIONS THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 33: ... 33 34 SIGNAL BOARD PB9966 BOTTOM FOIL SIDE ...
Страница 34: ... 35 36 POWER DEF BOARD PD0154 BOTTOM FOIL SIDE ...
Страница 35: ... 37 CRT DRIVE BOARD PB9973 BOTTOM FOIL SIDE ...
Страница 36: ... 38 3L BOARD PB9398 BOTTOM FOIL SIDE ...
Страница 38: ... 40 SPECIFIC INFORMATIONS MEMO ...
Страница 40: ......