7. Parts mounting and routing dressing of wirings should be the same as that used originally. For safety purposes, insulating materials such as
isolation tube or tape are sometimes used and printed circuit boards are sometimes mounted floating. Also make sure that wirings is routed
and clamped to avoid parts that generate heat and which use high voltage. Always follow the manufactured wiring routes / dressings.
8. Always ensure that all internal wirings are in accordance before re-assembling the external casing after a repairing completed. Do not allow
internal wiring to be pinched by cabinets, panels, etc. Any error in reassembly or wiring can result in electrical leakage, flame, etc., and may
be hazardous.
9. NEVER remodel the product in any way. Remodeling can result in improper operation, malfunction, or electrical leakage and flame, which
may be hazardous.
10. Touch current check. (After completing the work, measure touch current to prevent an electric shock.)
Plug the AC cord directly into the AC outlet. Do NOT use an isolation transformer for this check.
Connect a measuring network for touch currents between each exposed metallic part on the set and a good earth ground such as a
water pipe.