Preparing Filters

1. Open the air inlet grille and remove the air 

fi

lters.

2. Attach the 

fi

lters. 

Loading Batteries (when use wireless operation.)

1. Remove the slide cover.
2. Insert 2 new batteries (AAA type) 

following the (+) and (–) positions.

Clock Setup

1. Push 

 by tip of the pencil.

If timer indication is 

fl

ashing, go to the next step 2.

2. Press 

 or 

 : adjust the time.

3. Press 

 : Set the time.

Remote Control Reset

Push 

 by tip of the pencil or

1. Remove the batteries.

2. Press 

.

3. Insert the batteries.

INDOOR UNIT DISPLAY

1

PREPARATION BEFORE USE

2

AIR FLOW DIRECTION

Note:

  The provided Remote Controller is a wireless type, which also can be 

used as a wire. Please see “How to Connect The Remote Controller 
for Wired Operation”, located in installation instruction, in case of wired 
control is required.

  In wire operation, remote controller will return to initial condition 

(PRESET, TIMER and CLOCK will return to initial condition) when user 
shutdown power supply of Air conditioner.

REMOTE CONTROL

4  

AUTOMATIC OPERATION

6

To automatically select cooling, heating, or fan only operation

1. Press 

02'(

 : Select Auto A.

2. Press 

 : Set the desired temperature. Min. 17°C, Max. 30°C.

3. Press 

)$1

 : Select AUTO, LOW  , LOW+ 

, MED 

MED+ 

, HIGH 

 or Quiet 

1. Press 

02'(

 : Select Cool 

, Heat 

, or Fan only 

.

2. Press 

 : Set the desired temperature. Min. 17°C, Max. 30°C.

  Fan Only: No temperature indication

3. Press 

)$1

 : Select AUTO, LOW  , LOW+ 

, MED 

MED+ 

, HIGH 

 or Quiet 

COOLING / HEATING / FAN ONLY 
OPERATION

5

DRY OPERATION

7

For dehumidi

fi

cation, a moderate cooling performance is controlled 

automatically.

1. Press 

02'(

 : Select Dry 

.

2. Press 

 : Set the desired temperature. Min. 17°C, Max. 30°C.

Note: 

DRY mode fan speed is set to Auto only.

Hi POWER OPERATION

8

To automatically control room temperature and air

fl

ow for faster cooling or 

heating operation (except in DRY and FAN ONLY mode)

Press 

+L32:(5

: Start and stop the operation.

1

Press 

),;

 : Move the louver 

in the desired vertical direction.

2

Press 

FIX

 : Move the 

louver in the desired horizontal 
direction.

3

Press 

6:,1*

 : For select 

louver swing operation.

Vertical 

(Up-Down)

Swing

Horizontal 

(Left-Right) 

Swing

Swing off

Up-Down 

Left-Right 

Swing

Pi

Pi

Pi

Pi Pi

 

Vertical (Up-Down) swing

 

Horizontal (Left-Right) swing

Note:

  Do not move the louver manually by hands or others.

  The louver may automation positioning by some operation mode.

  Display brightness can be adjusted, follow procedure on  .

ͤ

 Require Wireless LAN connecting adapter which available as accessory.

1

ECO (White)

2

Wi-Fi access (White) 

ͤ

3

4

Timer (White)

5

Operation Mode
- Cool (Blue)
- Heat (Orange)

1

Infrared signal emitter

2

Memory and Preset button (PRESET)

3

Start/Stop button

4

Mode select button (MODE)

5

Air 

fl

 ow/HADA CARE FLOW button

6

Fireplace/8°C button

7

ECO button

8

Comfort sleep button (COMFORT SLEEP)

9

Weekly timer (ON/OFF)

!

Temp for Weekly timer

"

On timer button (ON)

#

Set clock button (CLOCK)

$

Check button (CHECK)

%

Filter reset button (FILTER)

&

Temperature button (TEMP)

(

Swing louver button (SWING)

)

Fan speed button (FAN)

~

Set louver Left-Right button (FIX 

W

)

+

Set louver Up-Down button (FIX 

X

)

,

High power button (Hi POWER)

-

Power selection/Silent button (P-SEL/SILENT)

.

Program P1 - P4

/

Day/Edit button

:

Setup button (SET)

;

Off timer button (OFF)

<

Clear button (CLR)

=

Reset button (RESET)

1

2
3
4

6

5

7
8
9
0
!
@
#
$
%

&

^

t
y

*
(

w

=

)
-

e
r

q

y

Plasma Ion button (PURE)

 

   

 

 

(see detail in the Installation Manual

).

PURE (White)

)

Содержание 24E2AVSG-A

Страница 1: ...1120650280 OWNER S MANUAL R32 AIR CONDITIONER SPLIT TYPE For general public use Indoor unit Outdoor unit RAS 18 22 24E2AVSG A RAS 18 22 24E2KVSG A ...

Страница 2: ...m without continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater In order to avoid fire explosion or injury do not operate the unit when harmful gases e g flammable or corrosive are detected near the unit WARNING Do not expose your body directly to cool or warm air for a long time Do not insert your finger or any article into the ...

Страница 3: ...mal etc Do not step or put anything on the indoor outdoor unit It may cause an injury or damage the unit Do not touch aluminium fin because it may cause an injury Before cleaning the unit turn off the main switch or the circuit breaker When the unit won t be used for a long time turn off the main switch or the circuit breaker It is recommended that maintenance be performed by a specialist when the...

Страница 4: ...lect Dry 2 Press Set the desired temperature Min 17 C Max 30 C Note DRY mode fan speed is set to Auto only Hi POWER OPERATION 8 To automatically control room temperature and airflow for faster cooling or heating operation except in DRY and FAN ONLY mode Press L 32 5 Start and stop the operation 1 Press Move the louver in the desired vertical direction 2 Press FIX Move the louver in the desired hor...

Страница 5: ...power consumption to 100 75 or 50 and can be implemented by POWER SELECTION The lower percentage the higher saving and also longer compressor lifetime Note When the level is selected POWER SEL level flashes on remote LCD display for 3 seconds In case of 75 and 50 level number 75 or 50 also flashes for 2 seconds Due to the reason that POWER SELECTION function limits the maximum current inadequate c...

Страница 6: ...he button is pressed once during Cool or Dry mode the fan will continue to run for other 30 minutes then it will turn off automatically This will reduce the moisture in the indoor unit 2 To stop the unit immediately press the more 2 times within 30 seconds TEMPORARY OPERATION In case of the misplaced or discharged remote control Pressing the RESET button the unit can start or stop without using th...

Страница 7: ...ss to enter WEEKLY TIMER setting 2 Press to select desired day in sequence The sequence of day symbol appears on the LCD SU t MO t TU t WE t TH t FR t SA WEEKLY SUMO TUWETHFRSA All day 3 Press to select the program number The program 1 is ready for setting while is pressed PG 1 appears on the LCD Press to change the program number in the sequence program 1 to program 4 PG 1 PG 2 PG 3 PG 4 4 Press ...

Страница 8: ...ws the next program The program after reactivation is related to the clock time To delete programs The individual program 1 Press The day of the week and the program number is displayed Select the day to delete the program 2 Press to select the program number to be deleted 3 Press ON or OFF timer will be cleared and the LCD will blink 4 Press to delete the program Press while the LCD is blinking T...

Страница 9: ...MEMO ...

Страница 10: ...MEMO ...

Страница 11: ......

Страница 12: ...1120650280 ...

Отзывы: