5
20AR21
20AR31
CIRCUIT PROTECTION
The receiver is protected by a 3.15A fuse (F701),
mounted on PWB-A, wired into one side of the AC
line input.
+B DC REGULATOR CONFIRMATION
The + B DC output voltage adjustment is not included
in this circuit.However, should confirmation be
reguired proceed as follows.
1. Actuate receiver with 220V AC input voltage.
2. Receive a local channel.
3. Connect positive lead of digital voltmeter to C754
positive side on PWB-A ; negative lead to chassis
ground.
4. Confirm this voltage reading is as below.
CAUTION: The reading should be 130.0 ± 2.0V
DC to ensure normal function and circuitry
reliability.
X-RADIATION PROTECTOR CIRCUIT TEST
After service has been performed on the horizontal
deflection system, high voltage system, B+ system,
test the X-Radiation protection circuit to ascertain
proper operation as follows:
1. Apply 220V AC using a variac transformer for accurate
input voltage.
2. Allow for warm up and adjust all customer controls
for normal picture and sound.
3. Receive a good local channel.
4. Connect a digital voltmeter to TP653 and make sure
that the voltmeter reads 21.4 ± 1.5 V.
5. Apply external 27.9V DC at TP653 by using an
external DC supply, TV must be shut off.
6. To reset the protector, unplug the AC cord and make
a short circuit between TP651 and TP652. Now make
sure that normal picture appears on the screen.
7. If the operation of the horizontal oscillator does not
stop in step 5, the circuit must be repaired before the
set is returned to the customer.
HIGH VOLTAGE CHECK
High voltage is not adjustable but must be checked
to verify that the receiver is operating within safe
and efficient design limitations as specified checks
should be as follows:
1. Connect an accurate high voltage meter between
ground and anode of picture tube.
2. Operate receiver for at least 15 minutes at 110~220V
AC line voltage, with a strong air signal or a properly
tuned in test signal.
3. Receve a good local channel.
4. The voltage should be approximately, 25.5kV (at
pictuer MAX Bright center condition).
If a correct reading cannot be obtained, check circuitry
for malfunctioning components.
INSTALLATION AND SERVICE INSTRUCTIONS
Note:
(1) When performing any adjustments to resistor controls and transformers use non-metallic
screwdrivers or TV alignment tools.
(2) Before performing adjustments, the TV set must be on at least 15 minutes.
Содержание 20AR21
Страница 14: ...13 6 5 4 3 2 1 A B C D E F G H 20AR21 20AR31 MODEL 20AR21 CHASSIS LAYOUT ...
Страница 15: ...14 6 5 4 3 2 1 A B C D E F G H 20AR21 20AR31 MODEL 20AR31 CHASSIS LAYOUT ...
Страница 16: ...15 6 5 4 3 2 1 A B C D E F G H 20AR21 20AR31 BLOCK DIAGRAM 1 ...
Страница 17: ...17 20AR21 20AR31 16 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H MODEL 20AR21 BLOCK DIAGRAM 2 ...
Страница 18: ...19 20AR21 20AR31 18 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H MODEL 20AR31 BLOCK DIAGRAM 2 ...
Страница 20: ...21 6 5 4 3 2 1 A B C D E F G H 20AR21 20AR31 SCHEMATIC DIAGRAM CRT Unit DUNTKA542WEA3 ...
Страница 23: ...27 20AR21 20AR31 26 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H MODEL 20AR31 SCHEMATIC DIAGRAM MTS MODULE Unit ...
Страница 24: ...28 6 5 4 3 2 1 A B C D E F G H 20AR21 PWB A MAIN Unit Wiring Side PRINTEDWIRING BOARD ASSEMBLIES 20AR31 ...
Страница 25: ...29 6 5 4 3 2 1 A B C D E F G H 20AR21 20AR31 PWB A MAIN Unit Chip Parts Side ...
Страница 26: ...30 6 5 4 3 2 1 A B C D E F G H 20AR21 20AR31 PWB B CRT Unit Wiring Side PWB B CRT Unit Chip Parts Side ...
Страница 36: ...TOSHIBA CORPORATION 1 1 SHIBAURA 1 CHOME MINATO KU TOKYO 105 8001 JAPAN ...