D4163443A
22
(2) Reading the register
To read data from a register, send ', (comma)', 'R', 'Q' and [CR] code following the address. For example, to read
data in address 0x91, send a command, as follows:
The camera responds to the read request, as follows (Data's max-length is 8 bytes):
Actually, the camera responds to the read request as minimum data length: For example, to read data 0x10 to
address 0x91, the camera responds as follows:
‘9’
(0x39)
‘1’
(0x31)
‘ , ’
(0x2C)
‘R’
(0x52)
‘Q’
(0x51)
[CR]
(0x0D)
Data
8th by te
Data
7th by te
Data
6th by te
Data
5th by te
Data
4th by te
Data
2nd by te
Data
1st by te
[CR]
(0x0D)
Data
3rd by te
‘1’
(0x31)
‘0’
(0x30)
[CR]
(0x0D)
Содержание CSC12M25BMP19