![Toshiba teli BU030 Скачать руководство пользователя страница 50](http://html.mh-extra.com/html/toshiba-teli/bu030/bu030_instruction-manual_1138533050.webp)
49 / 76
D4213050G
Copyright © 2013 TOSHIBA TELI CORPORATION, All rights reserved.
www.toshiba-teli.co.jp
- Set the number of frames to exposure (In Bulk mode)
Set the number of frames to exposure to
“TriggerAddtionalParameter”. Setting value is Integer type.
TriggerAdditionalParameter
Value
Minimum (*)
0 [frame]
Maximum
255 [frames]
* initial factory setting
- Set trigger delay (HardwareTrigger operation only)
Set the following value to “TriggerDelay” register. Setting value is Float type.
Adds delay time from trigger edge to exposure start.
TriggerDelay
Value
Minimum (*)
0.00[
μs]
Maximum
2000000
.00[μs]
* initial factory setting
- Grabs image stream by software trigger
When executes
“TriggerSoftware” register command, software trigger command is generated. Camera
starts exposure by receiving software trigger command.
● Note
In SoftwareTrigger operation, the delay time from
“TriggerSoftware” to exposure is not guaranteed.