175 / 177
Copyright © 2018 - 2020 Toshiba Teli Corporation, All rights reserved.
https://www.toshiba-teli.co.jp/en/
DAA00195C
● Note
In Bulk function, you may want to set “Continuous” to “AcquisitionMode” register.
You can set “MultiFrame”, but acquisition frame number is limited by “AcquisitionFrameCount.
Trigger
Exposure
AcquisitionMode = MultiFrame
AcquisitionFrameCount = 2
TriggerMode = On
TriggerSequence = 6
TriggerAdditionalParameter = 3
Acquisition
Command
Start
Frame 1
Frame 2
Frame 3
The trigger can be input in arbitrary timing.
VD
AcquisitionFrameRate
Stop
Start
Frame 1
Counter is reset.
USB Streaming
Frame 1
Frame 1
*Exposure time is determined by ExposureTime setting.
TriggerAdditionalParameter
AcquisitionFrameCount
Stream
stops
This exposure is
discarded.
Frame 2
*Exposure overlaps sensor readout.