25 / 69
Copyright © 2016-2018 TOSHIBA TELI CORPORATION, All rights reserved.
http://www.toshiba-teli.co.jp/en/index.htm
D4272607A
Timing Specification
For getting fastest farmerate, shatter speed
≦
readout time.
(1) Horizontal timing
● All pixel readout (* following timing figure: BC505LMG 3tap)
LVAL
DVAL
DATA OUT
b
c
a
・・・・・・
・・・・・・
1H
3
2
1
6
5
4
9
8
7
2442
2441
2440
2445
2444
2443
2448
2447
2446
1CLK=41.5/64/83MHz
1CLK=41.5MHz
unit: CLK
Model
CameraLink Tap
a
b
c
BC302LMG
1tap
4
8
2048
2tap
1024
3tap
683
BC505LMG
BC505LMC
1tap
2448
2tap
1224
3tap
816
1CLK=64MHz / 83MHz
unit: CLK
Model
CameraLink Tap
a
b
c
BC302LMG
1tap
4
8
2048
2tap
1024
3tap
any
683
BC505LMG
BC505LMC
1tap
4
2448
2tap
1224
3tap
any
816
Horizontal sync frequency=1H
unit
:
KHz
Model
CameraLink Tap
Clk frequency (1CLK)
41.5MHz
64MHz
83MHz
BC302LMG
1tap
20.15
31.20
40.30
2tap
40.07
62.04
80.14
3tap
59.73
any
any
BC505LMG
BC505LMC
1tap
16.87
26.13
33.75
2tap
33.59
52.01
67.17
3tap
50.14
any
any