ENGLIS
H ( EN )
39
20. ADVANCED OPTIONS
Vigilec Mini (V1N) and Vigilec Mono (V1M) have a number of advanced options that are disabled by
default.
Level deactivated/activated (LEV ON / LEV OFF)
Allows to enable or disable the level detection by means of probes.
Pumping direction selection (OUT / IN)
Allows to select the operating mode of the probes, being able to select emptying mode
(well) or filling mode (tank).
Excessive frequency of starts (OFF / ON)
Allows to enable or disable the excessive frequency of starts protection.
Anti-blocking protecion (OFF / ON)
Allows to enable or disable the pump anti-blocking protection.
Manual latched/unlatched mode(HAND)
Allows the activation of the manual latched mode, whereby the button needs not be held down
while in manual mode. Allows to return to the unlatched manual mode.
To learn more about these options and how to activate them, please contact us at
Note: The counters of hours, starts, alarms and current of the last alarm will not be deleted.
Distribuido por Adajusa