Important Safety Instructions

CAUTION!

To reduce the risk of electric shock and fire, do not remove the cover of this device. There

are no user serviceable parts inside. Please refer all servicing to licensed service technicians.

CAUTION!

The international symbol of a lightning bolt inside a triangle is intended to alert the user to

uninsulated “dangerous voltage” within the device’s enclosure. The international symbol of an
exclamation point inside a triangle is intended to alert the user to the presence of important
operating, maintenance and servicing information in the manual accompanying the device.

CAUTION!

To prevent electrical shock, match wide blade of plug to wide slot, fully insert.

CAUTION!

To reduce the risk of electrical shock, do not expose this equipment to rain or moisture.

1. Read Instructions—All safety and operating instructions
should be read before operating the device.

2. Retain Instructions—The safety and operating
instructions should be retained for future reference.

3. Heed Warnings—All warnings on the device and in the
operating instructions should be adhered to.

4. Follow Instructions—All operating and safety instructions
should be followed.

5. Water & Moisture—The device should never be used in,
on or near water for risk of fatal shock.

6. Ventilation—The device should always be located in such
a way that it maintains proper ventilation. TOT Series
Stand-Alone models should never be placed in a built-in
installation or anywhere that may impede the flow of air
through its

.

ventilation slots

7. Heat—Never locate the device near heat sources such as
radiators, floor registers, stoves or other heat generating

-

devices.

8. Power Cord Protection—Power cables should be routed
so they are not likely to be stepped on or crushed by items
placed on them or against them. Special attention should
be paid to areas where the plug enters a socket or fused
strip and where the cord exits the device.

9. Periods Of Non-Use—The device should be unplugged
when not being used for extended periods.

1 . Dangerous Entry—Care should be taken that no foreign

0

objects or liquids fall or are spilled inside the device.

1 . Damage Requiring Service—The device should be

1

serviced by licensed technicians when:

• The plug or power supply cord has been damaged.

• Objects have fallen or liquid has spilled inside the device.

• The device has been exposed to moisture.

• The device does not appear to be operating properly or
exhibits a marked change in performance.

• The device has been dropped or the enclosure becomes
damaged.

1 . Service—The device should always be serviced by

2

licensed technicians. Only replacement parts specified by
the manufacturer should be used. The use of unauthorized
substitutions may result in fire, shock, or other hazards.

1 . Do not position the equipment so that it is difficult to

3

operate the disconnecting device (power cord).

14. If the equipment is used in a manner not specified by
the manufacturer, the protection provided by the
equipment may be impaired.

15. The power switch should be in the “off” position when
connecting or disconnecting equipment from a Torus Power
unit.

16

Some units can be very heavy, please use

.

CAUTION

safe practices when lifting.

³

18 kg (39.7 lb)

³

32 kg (70.5 lb)

³

55 kg (121.2 lb)

1

www.TorusPower.com

Owner’s Manual                     Power Conditioners                 Audio / Video Power Isolation Units                      TOT Series Manual

REV.2016/07/26

Содержание TOT AVR

Страница 1: ...TOT Series Manual North American and International Models without optional faceplate Receptacle Panel of International Models CE model shown North American Models...

Страница 2: ......

Страница 3: ...INI CE SMSS 7 Circuit Schematic International TOT MAX CE TOT MAX CE SMSS 8 Circuit Schematic International TOT MINI UK TOT MINI UK SMSS TOT MINI AUS SMSS 9 Circuit Schematic International TOT MAX UK T...

Страница 4: ...such as radiators floor registers stoves or other heat generating devices 8 Power Cord Protection Power cables should be routed so they are not likely to be stepped on or crushed by items placed on th...

Страница 5: ...small or mid power AV systems or dedicated to video components ie flat panel TVs projectors or audio components i e media sources powered speakers source components etc The is rated at 15A North Amer...

Страница 6: ...er Outlet North American 5 15R Power Inlet Fuse Holder USB Charger 3 RK Faceplate Model Number TOT MAX UK Model Number TOT MAX AUS Model Number TOT MINI UK Model Number TOT MINI AUS International Mode...

Страница 7: ...15R SCHUKO CEE 7 7 OUTPUT USB 5 1VDC nominal 2300mA maximum WEIGHT SAU 25 1 lbs 11 4kg 38 9 lbs 17 7kg 25 5 lbs 11 6kg 49 5 22 5 lbs kg WEIGHT RACK 26 0 lbs 11 8kg 39 8 lbs 18 1kg 26 4 lbs 12 0kg 39...

Страница 8: ...del TOT MINI 5 Circuit Schematic North American Model TOT MINI SMSS Circuit Schematic North American Model TOT MAX www TorusPower com Owner s Manual Power Conditioners Audio Video Power Isolation Unit...

Страница 9: ...n Model TOT MAX SMSS Circuit Schematic International TOT MINI CE Circuit Schematic International TOT MINI CE SMSS www TorusPower com Owner s Manual Power Conditioners Audio Video Power Isolation Units...

Страница 10: ...uit Schematic International TOT MAX CE Circuit Schematic International TOT MAX CE SMSS www TorusPower com Owner s Manual Power Conditioners Audio Video Power Isolation Units TOT Series Manual REV 2016...

Страница 11: ...l TOT MINI UK Circuit Schematic International TOT MINI UK SMSS Circuit Schematic International TOT MINI AUS SMSS www TorusPower com Owner s Manual Power Conditioners Audio Video Power Isolation Units...

Страница 12: ...al TOT MAX UK Circuit Schematic International TOT MAX UK SMSS Circuit Schematic International TOT MAX AUS SMSS www TorusPower com Owner s Manual Power Conditioners Audio Video Power Isolation Units TO...

Страница 13: ...emovable to bolt the unit to a surface All units are 2U height Faceplate RK faceplate width is 19 Shelf type faceplate width is 12 5 SMSS An SMSS Series Mode Surge Suppressor is available for this uni...

Страница 14: ...removable to bolt the unit to a surface All units are 2U height Faceplate RK faceplate width is 19 Shelf type faceplate width is 12 5 11 SMSS An SMSS Series Mode Surge Suppressor is available for this...

Страница 15: ...removable to bolt the unit to a surface All units are 2U height Faceplate RK faceplate width is 19 Shelf type faceplate width is 12 5 12 SMSS An SMSS Series Mode Surge Suppressor is available for this...

Страница 16: ...able to bolt the unit to a surface All units are 2U height Faceplate With RK faceplate width is 19 Shelf type faceplate width is 12 5 SMSS An SMSS Series Mode Surge Suppressor is available for this un...

Страница 17: ...emovable to bolt the unit to a surface All units are 2U height Faceplate With RK faceplate width is 19 Shelf type faceplate width is 12 5 SMSS An SMSS Series Mode Surge Suppressor is available for thi...

Страница 18: ...emovable to bolt the unit to a surface All units are 2U height Faceplate With RK faceplate width is 19 Shelf type faceplate width is 12 5 SMSS An SMSS Series Mode Surge Suppressor is available for thi...

Страница 19: ...US TOT MAX AUS SMSS This is an installation drawing for the TOT MAX AUS The four rubber feet at the base of the unit are removable to bolt the unit to a surface All units are 2U height Faceplate With...

Страница 20: ...Rev 2016 07 26...

Отзывы: