1. Position the machine on a level surface, stop the
engine, and set the parking brake.
2. Unlatch the seat and tilt the seat up.
3. With the engine cool, check the overflow bottle level.
The fluid needs to be up to the bump on the outside
of the overflow bottle (Figure 60).
4. If the coolant level is low, add a 50/50 mix of
extended life antifreeze/Dex-Cool® and water to
the overflow bottle (Figure 60).
5. Add the 50/50 coolant mix to the overflow
bottle and fill it to the indicator line on the bottle
(Figure 60).
Figure 60
1.
Antifreeze overflow bottle
2.
Indicator line on side of
overflow bottle
Cleaning the Hydraulic Oil Cooler and
Radiator Screen
Service Interval:
Before each use or daily
Before each use, check and clean the radiator screen
and oil cooler. Remove any build-up of grass, dirt or
other debris from the oil cooler and radiator screen with
compressed air (Figure 61).
Figure 61
1.
Hydraulic oil cooler
3.
Radiator screen
2.
Left rear tire
Changing the Engine Coolant
Service Interval:
Yearly
Contact an Authorized Service Dealer for changing the
coolant.
45
Содержание Z580-D Z Master 74266CP
Страница 6: ...Slope Chart 6 ...
Страница 8: ...98 5954 105 7798 107 1613 107 1857 107 1860 107 1861 107 1864 8 ...
Страница 9: ...107 2102 107 2112 107 2114 104 2449 108 5955 108 5957 108 5981 9 ...
Страница 64: ...Schematics Wire Diagram Rev A 64 ...
Страница 65: ...Notes 65 ...
Страница 66: ...Notes 66 ...