![Toro TimeCutter 74750 Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/toro/timecutter-74750/timecutter-74750_operators-manual_1132318034.webp)
Charging the Battery
Service Interval:
Before storage—Charge the battery and
disconnect battery cables.
1.
Remove the battery from the chassis; refer to
the Battery (page 33)
.
2.
Charge the battery for a minimum of 1 hour at 6 to
10 amps.
Note:
Do not overcharge the battery.
3.
When the battery is fully charged, unplug the charger
from the electrical outlet, then disconnect the charger
leads from the battery posts (
Figure 40
1.
Positive (+) battery post
3.
Red (+) charger lead
2.
Negative (–) battery post
4.
Black (–) charger lead
Installing the Battery
1.
Position the battery in the tray (
2.
Using the fasteners previously removed, install the
positive (red) battery cable to the positive (+) battery
terminal.
3.
Using the fasteners previously removed, install the
negative battery cable to the negative (-) battery
terminal.
4.
Slide the red terminal boot onto the positive (red)
battery post.
5.
Secure the battery with the hold-down (
6.
Lower the seat.
Servicing the Fuses
The electrical system is protected by fuses. It requires
no maintenance; however, if a fuse blows, check the
component/circuit for a malfunction or short.
Fuse type:
•
Main—F1-30 A, blade-type
•
Charge Circuit—F2-25 A, blade-type
1.
Remove the screws securing the control panel to the
machine.
Note:
Retain all fasteners.
2.
Lift the control pane up to access the main wire harness
and fuse block (
).
3.
To replace a fuse, pull out on the fuse to remove it
(
).
30
25
30
25
G014921
2
1
Figure 41
1.
Main—30 A
2.
Charge circuit—25 A
4.
Return the control panel to its original position.
Note:
Use the screws removed previously to secure
the panel to the machine.
34
Содержание TimeCutter 74750
Страница 47: ...Schematics Electrical Diagram Rev A 47 ...