![Toro TimeCutter 74750 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/toro/timecutter-74750/timecutter-74750_operators-manual_1132318029.webp)
Servicing the Engine Oil
Oil Type:
Detergent oil (API service SF, SG, SH, SJ, or
higher)
Crankcase Capacity:
1.0 L (34 oz) when you do not change
the filter; 1.05 L (36 oz) when you change the filter.
Viscosity:
See the table below.
SAE 5W
-30, 10W -30
SAE 30
SYNTHETIC 5W -20, 5W -30, 10W -30
g029683
Figure 30
Checking the Engine-Oil Level
Service Interval:
Before each use or daily
Note:
Check the oil when the engine is cold.
WARNING
Contact with hot surfaces may cause personal
injury.
Keep hands, feet, face, clothing and other body
parts away the muffler and other hot surfaces.
Important:
Do not overfill the crankcase with oil and
run the engine; engine damage may result.
1.
Park the machine on a level surface.
2.
Disengage the blade-control switch (PTO).
3.
Shut off the engine, wait for all moving parts to stop,
and remove the key before leaving the operating
position.
4.
Check the engine-oil level (
B
A
C
D
E
G029368
F
G
H
I
J K
Figure 31
Changing the Engine Oil and Filter
Service Interval:
After the first 5 hours
Every 100 hours (change it more often under a heavy
load or in high temperatures).
Every 100 hours
Note:
Change the engine-oil filter more frequently when the
operating conditions are extremely dusty or sandy.
1.
Park the machine, so that the right side is slightly
lower than the left side, to ensure that the oil drains
completely.
2.
Disengage the blade-control switch (PTO).
3.
Shut off the engine, wait for all moving parts to stop,
and remove the key before leaving the operating
position.
4.
Drain the oil from the engine.
29
Содержание TimeCutter 74750
Страница 47: ...Schematics Electrical Diagram Rev A 47 ...