Reelmaster 3550--D
Page 5 -- 7
Electrical System
Troubleshooting
CAUTION
Remove all jewelry, especially rings and
watches, before doing any electrical trouble-
shooting or testing. Disconnect the battery
cables unless the test requires battery voltage.
For effective troubleshooting and repairs, there must be
a good understanding of the electrical circuits and com-
ponents used on this machine (see Chapter 8 -- Foldout
Drawings).
If the machine has any interlock switches by--passed,
reconnect the switches for proper safety and trouble-
shooting.
NOTE:
Use the Diagnostic Display (see Special Tools
in this chapter) to test Electronic Control Module inputs
and outputs when troubleshooting an electrical problem
on your Reelmaster.
Diagnostic Light
Reelmaster 3550--D machines are equipped with a
diagnostic light that indicates if the machine electrical
system is functioning correctly. The diagnostic light is lo-
cated on the control panel (Fig. 8).
When the ignition switch is moved to the RUN position
and the machine electrical system is functioning pro-
perly, the diagnostic light will be illuminated for approxi-
mately three (3) seconds and then will turn off. The light
should remain off during normal machine operation.
If the machine TEC controller detects an electrical sys-
tem malfunction (fault) during machine operation, the
diagnostic light will flash rapidly. The light will stop flash-
ing and will automatically reset when the ignition switch
is turned to the OFF position. The fault, however, will be
retained in controller memory and can be retrieved at a
future time (see Retrieving Fault Codes below).
If the diagnostic light does not illuminate when the igni-
tion switch is turned to the RUN position, possible
causes are:
D
The loopback connector located below the con-
trol panel is not connected to the machine wire har-
ness (Fig. 9).
D
The diagnostic light (or circuit wiring) is faulty.
D
TEC controller fuses are faulty (see Fuses in the
Component Testing section of this chapter).
D
The TEC controller is faulty.
Check electrical connections, controller fuses and the
diagnostic light to determine malfunction. Make sure
that the loopback connector is secured to the wire har-
ness connector.
1. Control panel
2. Diagnostic light
Figure 8
1
2
Figure 9
1. Control panel
2. Loopback connector
3. Harness connector
1
2
3
Содержание Reelmaster 3550-D
Страница 2: ...Reelmaster 3550 D This page is intentionally blank ...
Страница 4: ...Reelmaster 3550 D This page is intentionally blank ...
Страница 10: ...0 09375 Reelmaster 3550 D Page 2 2 Product Records and Maintenance Equivalents and Conversions ...
Страница 18: ...Reelmaster 3550 D Page 3 4 Kubota Diesel Engine This page is intentionally blank ...
Страница 20: ...Reelmaster 3550 D Hydraulic System Page 4 2 This page is intentionally blank ...
Страница 29: ...Reelmaster 3550 D Hydraulic System Page 4 11 This page is intentionally blank ...
Страница 74: ...Reelmaster 3550 D Page 6 4 Chassis This page is intentionally blank ...
Страница 85: ...Reelmaster 3550 D DPA Cutting Units Page 7 11 This page is intentionally blank ...
Страница 91: ...Reelmaster 3550 D DPA Cutting Units Page 7 17 This page is intentionally blank ...
Страница 95: ...Reelmaster 3550 D DPA Cutting Units Page 7 21 This page is intentionally blank ...
Страница 98: ...Reelmaster 3550 D DPA Cutting Units Page 7 24 This page is intentionally blank ...
Страница 100: ...Reelmaster 3550 D Foldout Drawings Page 8 2 This page is intentionally blank ...