Troubleshooting
CAUTION
Remove all
especially rings and
watches, before doing any electrical trouble-
ness from the vehicle unless the test requires
battery voltage.
jewelry,
shooting or testing. Disconnect the power har-
For effective troubleshooting and repairs, you must
have a good understanding of the electrical circuits (see
Chapter 6 – Electrical Diagrams) and components used
on this machine.
If the machine has the interlock switch by–passed, it
must be reconnected for proper troubleshooting and
safety.
Problem
Possible Causes
Brush rotates (but should not) when dump hopper is
raised.
Hopper down proximity switch is malfunctioning or
faulty.
Brush relay is faulty.
Hopper switch or circuit wiring is faulty.
Logic diode is faulty.
Brush does not rotate.
Hopper is raised (brush should only rotate when
hopper is fully lowered).
Hopper down proximity switch is malfunctioning or
faulty.
Problem with power or ground from vehicle (other
sweeper functions affected as well).
Fuse (20 Amp) is faulty (other sweeper functions
affected as well).
Brush switch or circuit wiring is faulty.
Brush relay or circuit wiring is faulty.
Hopper down relay or circuit wiring is faulty.
Logic diode is faulty.
Demand solenoid valve coil (S2) or circuit wiring is
faulty.
Brush solenoid valve coil (S3) or circuit wiring is faulty.
Hydraulic problem exists (see Chapter 3 – Hydraulic
System).
Electrical System
Page 4 – 2
Pro Sweep 5200
Содержание Pro Sweep 5200
Страница 2: ...This page is intentionally blank Pro Sweep 5200...
Страница 4: ...This page is intentionally blank Pro Sweep 5200...
Страница 10: ...This page is intentionally blank Safety Page 1 6 Pro Sweep 5200...
Страница 12: ...Rev A 0 09375 Pro Sweep 5200 Page 2 2 Product Records and Maintenance Equivalents and Conversions...
Страница 28: ...This page is intentionally blank Hydraulic System Page 3 12 Pro Sweep 5200...
Страница 33: ...Hydraulic System This page is intentionally blank Pro Sweep 5200 Page 3 17 Hydraulic System...
Страница 42: ...This page is intentionally blank Hydraulic System Page 3 26 Pro Sweep 5200...
Страница 54: ...This page is intentionally blank Electrical System Page 4 12 Pro Sweep 5200...
Страница 70: ...This page is intentionally blank Electrical Diagrams Page 6 2 Pro Sweep 5200...
Страница 71: ...Page 6 3 Electrical Schematic Pro Sweep 5200 Relays are shown as de energized All ground wires are black...