Pro Sweep
Page 4 -- 5
Electrical System
Problem
Possible Causes
Sweeper does not lower.
Control module has timed out due to 30 minutes of
inactivity.
Hopper safety support is installed on lift cylinder.
Diode D1 is faulty.
Down Float Latch relay or circuit wiring is faulty.
Down Latch Release relay or circuit wiring is faulty.
Solenoid valve coil (SV2) or circuit wiring is faulty.
Hydraulic problem exists (see Chapter 3 -- Hydraulic
System).
Sweeper offset does not function.
Control module has timed out due to 30 minutes of
inactivity.
Offset lockout proximity switch is out of adjustment.
Offset Lockout relay or circuit wiring is faulty.
Offset lockout proximity switch or circuit wiring is faulty.
Solenoid valve coil(s) (SV1) or circuit wiring is faulty.
Hydraulic problem exists (see Chapter 3 -- Hydraulic
System).
Electrical System
Содержание Pro Sweep 07066
Страница 2: ...Pro Sweep This page is intentionally blank ...
Страница 4: ...Pro Sweep This page is intentionally blank ...
Страница 10: ...Pro Sweep Page 1 6 Safety This page is intentionally blank ...
Страница 12: ...0 09375 Pro Sweep Page 2 2 Product Records and Maintenance Equivalents and Conversions ...
Страница 37: ...Pro Sweep Hydraulic System Page 3 21 This page is intentionally blank Hydraulic System ...
Страница 43: ...Pro Sweep Hydraulic System Page 3 27 This page is intentionally blank Hydraulic System ...
Страница 56: ...Pro Sweep Hydraulic System Page 3 40 This page is intentionally blank ...
Страница 92: ...Pro Sweep Electrical Diagrams Page 6 2 This page is intentionally blank ...
Страница 101: ...Page 6 11 Pro Sweep Power Wire Harness BLACK RED BLUE ...
Страница 102: ...Page 6 12 Pro Sweep Main Wire Harness Drawing CONTROL MODULE CONTROL MODULE ...