Checking and Adjusting the
Auger/Impeller Cable
Service Interval:
After the first 2 hours—Inspect the
auger/impeller cable and adjust it if
necessary.
Yearly—Inspect the auger/impeller cable and
adjust or replace it if necessary.
1.
Loosen the jam nut (
2.
Engage the auger/impeller lever and hold it in
place (
g360687
Figure 30
3.
Loosen or tighten the turnbuckle to adjust the
spring length to 6.6 cm (2-3/5 inches) as shown
in
g371834
Figure 31
1.
Turnbuckle
3.
Spring
2.
Jam nut
4.
6.6 cm (2-3/5 inches) while
the auger/impeller lever is
held down.
4.
Tighten the jam nut (
), ensuring that
there is slight tension on the cable.
5.
Turn on the machine and attempt to engage the
auger/impeller drive without moving the lock
switch back; if the auger rotates, loosen the
turnbuckle so that the auger does not engage.
6.
If the auger/impeller cable is properly adjusted
but a problem remains, contact an Authorized
Service Dealer.