Toro NO FOUND TMC-424E Скачать руководство пользователя страница 11

7

Set Program Start Times

NOTE:

 The TMC-424E enables a total of 16 unique start times to assigned to four programs 

in any combination totaling 16. For example, program 

A

 could have 12 start time assignments, 

which would leave four start time assignments available for programs 

B

C

 and 

D

.

1.  Turn the Function Dial to 

Start Times

. The start time hour digit(s) will begin flashing.

2.  Press the

or

button to select a start time number (01 to 16). 

   

NOTE:

 Any start time number currently assigned to another program can not be selected. If all 16 

start time assignments are in use, 

NONE

 will be displayed.

3.  Press the

or

button to select a start time hour (note the correct a.m./p.m. designation in 

the 12-hour clock mode).

   

NOTE:

 To remove a start time, select 

-- --:-- -- 

(Off), located between the hours of 11:00 p.m. 

and 12:00 a.m. (00 minutes).

4.  Press the

button to select minutes digits. Repeat step 3 to set start time minutes (00–59). 

5.  Repeat steps 2–4 to set additional start times for the selected program.

Set Watering Day Schedule

The TMC-424E series offers three watering day schedule formats. Each program can have any one 
of the following schedule formats:

Calendar Days 

– Use this scheduling method to select specific days of the week. 

Odd/Even

 – Schedules days by odd-or even-numbered calendar days.

NOTE:

 When an odd-numbered day schedule is used, watering will not occur on the 31st of any 

month and February 29th of a leap year.

Day Interval 

– Scheduling by Day Interval enables a specific number of days between watering to 

be selected. For example, selecting a 1-day Interval  
schedules watering to occur every day. A 2-day interval schedules watering  
to occur every-other day. A 31-day interval is the maximum schedule, providing watering only 
once every 31 days. Since the interval schedule is not tied to  
specific days of the week, you will also need to determine when the interval  
will start, by selecting the current day within the Interval. 

• Day Exclusion

 – When using the 

Odd/Even

 or

 Day Interval

 watering day schedule, watering 

will not always occur on the same days each week.  
To prevent watering on a specific days, for example, watering-restricted days, specific days of 
the week can be easily excluded from the schedule.

NOTE:

 Each program can only have one assigned watering schedule format.  

If either an Interval or Odd/Even schedule is currently set, it must be turned Off first to enable an 
optional format to be selected.

Содержание NO FOUND TMC-424E

Страница 1: ...PREV NEXT ON OFF Toro Modular Controller 4 to 24 Stations Toro Modular Controller 4 to 24 Stations Installation Programming Operation Installation Programming Operation User s Guide User s Guide...

Страница 2: ...ogram cycle and soak option provides 1 30 repeat cycles and soak time delay from 1 second to 60 minutes Day scheduling by Calendar days 1 31 day Interval or Odd Even days with selective day exclusion...

Страница 3: ...ons will remain in sequence without gaps Getting Started As an initial step we recommend that you take a few moments to browse through various sections of this User s Guide Also take the time jot down...

Страница 4: ...o Set Calendar Days 8 To Set Odd or Even Days 8 To Set Interval Days 8 Season Adjust Feature 9 Special Functions 10 Setting Station Delay Time Option 10 Setting Master Valve Pump Start Options 10 To S...

Страница 5: ...e Test Feature 19 Rain Delay Feature 20 Program Review Function 20 Installation Instructions 21 Cabinet Installation 21 Field Wire Connections 22 Flow Sensor Connection 23 Power Connection Indoor Mode...

Страница 6: ...tly above l 2 digit display identifies the station number or start time number currently selected 3 Navigation Buttons The and buttons are used to select function menu items All numeric On Off and Yes...

Страница 7: ...rary run time review To recap all program infor mation including start times run times and season adjust OFF Shuts off and prevents all automatic and manual watering operations 5 9V Battery Compartmen...

Страница 8: ...13 Flow sensor wiring terminals 14 Flow module master valve wiring terminal 15 Expansion module valve wiring terminals 16 Expansion module model TSM 4 shown 17 Wiring connection terminals S Rain Sens...

Страница 9: ...the highest station number The TMC 424E provides up to 16 watering cycle start time slots that can be assigned to the four programs in any combination For example program A could have 10 start times...

Страница 10: ...ram Memory Erase Feature on page 13 To simplify the programming process the following procedures are provided to define the operating parameters of one program at a time To begin set the program switc...

Страница 11: ...the following schedule formats Calendar Days Use this scheduling method to select specific days of the week Odd Even Schedules days by odd or even numbered calendar days NOTE When an odd numbered day...

Страница 12: ...n to select the Interval cycle length NOTE The cycle length can be set from 01 water every day to 31 water once every 31 days The Interval cycle starts at 01 and increases by 1 digit each day The wate...

Страница 13: ...TE By selecting the program Review function you can instantly view the total run time of each program adjusted for all operating factors including timed delays repeat cycles and Season Adjust See Prog...

Страница 14: ...enables a delay period to be entered between sequential stations within a watering cycle This option is generally used when irrigation demand exceeds the supply capacity as can occur when the supply i...

Страница 15: ...identifier will begin flashing 4 Press the button to exclude selected station or press the button to skip the station When excluded the station identifier will change from solid to hollow The next st...

Страница 16: ...etermines if multiple programs will be constrained to single file operation stacked or enabled to operate 2 or 3 programs concurrently overlap CAUTION Before selecting the overlap option ensure the hy...

Страница 17: ...Held Yes 3 Press the or buttons to select HH N Hand Held No Selecting Display Language Option The TMC 424E displays word prompts in English ENG by default and offers five additional languages prefere...

Страница 18: ...ion Dial is turned The station will turn off automatically at Midnight IMPORTANT Flow thresholds do not apply during True Manual and Timed Manual operations Timed Manual Operation 1 Turn the Function...

Страница 19: ...quence Automatic mode will resume when the manual operation is finished To turn off an active station and start the next station in sequence press the button To end manual operation at any time turn t...

Страница 20: ...ediately disable station and flow module master valve operation if flow rate exceeds a critical flow threshold NOTE The actual or Learned flow rate for each station should be established prior to sett...

Страница 21: ...low is detected above this setting 2 Press the or button to select a value from 01 to 99 PPS pulses per second Select Off to disable this threshold NOTE Refer to page 28 for important flow sensor perf...

Страница 22: ...assigned to flow monitoring will be automatically recorded the first time it is operated For PPS GPM conversion information see chart on page 28 12 Press the button Repeat the flow sensor setup parame...

Страница 23: ...ration IMPORTANT Flow thresholds do not apply during Valve Test operation 1 Turn the Function Dial to Valve Test The display will show 2 M 2 minutes of run time per station 2 Press the or buttons to c...

Страница 24: ...by one at each day change Automatic operation will resume when the watering delay day number is no longer displayed 4 To terminate the rain delay function turn the Function Dial to OFF 5 Press the but...

Страница 25: ...ommended NOTE Install electrical conduit as specified by applicable electrical and or building codes Wire electrical conduit and conduit fittings are not provided Selecting an Appropriate Installation...

Страница 26: ...cable that has at least one conductor for each valve connection and one conductor to provide a valve common connection 1 Route the valve control wires between the valves and the controller 2 Attach th...

Страница 27: ...module as follows Black to negative and Red to positive NOTE Flow Sensor wiring polarity must be correct to enable operation 3 If the master valve circuit is used connect either solenoid wire to the...

Страница 28: ...g to the illustration install the strain relief and tighten securely using appropriate hand tools NOTE Power cord assembly will vary by controller model 3 Insert the power cord through the strain reli...

Страница 29: ...er supply to the controller 3 Route the AC power and equipment ground wires from the power source through the conduit and into the transformer compartment NOTE The controller terminal block accepts wi...

Страница 30: ...he sensor automatically resets or is bypassed enabling the controller to return to automatic operation the controller will return to normal program operation 1 Route the sensor wires from the device i...

Страница 31: ...TMR 1 remote receiver plug assembly according to the user s guide provided with the TMR 1 kit 2 Route the receiver power wires and control cable into the cabinet through one of the available knock out...

Страница 32: ...92 8 484 3 40 3 2 6 4 10 8 67 5 114 2 334 0 553 0 45 3 6 7 2 12 1 76 0 128 4 375 8 621 7 50 4 0 8 0 13 4 84 5 142 6 417 4 690 4 55 4 4 8 8 14 7 93 0 156 8 458 9 759 2 60 4 8 9 6 16 0 101 5 171 0 500 5...

Страница 33: ...one or two Flow Modules each utilizing the individual Master Valve control output NOTE The maximum total current load permitted is 1 20A 24 VAC The valve and relay loads shown in the chart are based o...

Страница 34: ...noid pump start relay and or shorted wire splice FLOW or NFLOW Flow sensor alarms When flow monitoring is used the FLOW error message will be displayed when a station experiences an over under or crit...

Страница 35: ...Delay No All Off SD Master Valve Operation by Program Yes All on MV A Y Master Valve Exclusion by Station No No stations excluded MVS N Pump Delay No All Off PD Pump Enable No All Off during station...

Страница 36: ...VAC 10 50 60 Hz 30 VA Europe and Australia Internal Transformer TUV Approved SAA Approved Input 230 VAC 10 50 60 Hz Output 24 VAC 10 50 60 Hz 30 VA Maximum Load Per Station 0 5A 24 VAC Maximum Load P...

Страница 37: ...est Toro distributor or outside the U S call 951 688 9221 This warranty does not apply where equipment is used or installation is performed in any manner contrary to Toro s specifications and instruct...

Страница 38: ...Notes 34...

Страница 39: ...Notes 35...

Страница 40: ...ller into a different outlet so that the irrigation controller and receiver are on different branch circuits If necessary the user should consult the dealer or an experienced radio television technici...

Отзывы: