Removing the Master Boom
Manifold Valve
1.
Remove flange clamps and gaskets that secure
the manifold for the master-boom valve (
) to the master-boom bypass valve, agitation
valve, and 90° flanged elbow (at the end of the
hose for the flow meter).
Note:
Retain the flange clamps and gaskets
for installation in
Manifold Valve (page 84)
.
g033590
Figure 114
1.
Flange (agitation-valve)
4.
Flange clamp
2.
Flange
(bypass—master-boom
valve)
5.
Gasket
3.
Manifold (master-boom
valve)
6.
3-pin connector (valve
actuator—master-boom
valve)
2.
Remove the retainer that secure the 90°
outlet fitting to the manifold coupling for the
master-boom valve (
g033591
Figure 115
1.
Manifold (master-boom
valve)
4.
Flange-head bolt (1/4 x
3/4 inch)
2.
Valve mount
5.
Retainer
3.
Flange locknut (1/4 inch)
6.
Socket (90° outlet fitting)
3.
Remove the flange-head bolt (1/4 x 3/4 inch)
and flange locknut (1/4 inch) that secure the
master-boom valve to the valve mount and
remove the valve manifold from the machine
(
).
Note:
Retain the flange-head bolt, flange
locknut, and retainer for installation in
the Master Boom Manifold Valve (page 84)
.
79