Boom-Width Settings
The boom-width settings are pre-populated at the
manufacturing plant (
).
Calibration Screen
To access the Calibration screen, press button 2 on
the Main Menu screen (
) until you reach
Calibration, and press button 4 to select Calibration.
Note:
Pressing button 5 at any time cancels
calibrations. If you do so, the machine will
automatically use the current calibration rates.
g034322
Figure 31
Flow Calibration
Perform the flow calibration before using the machine
for the first time, if you change the nozzles, or as
needed.
Note:
It is recommended to perform a
nozzle-uniformity test before starting a Flow
Calibration.
1.
Set the machine into manual mode, close
the boom-sections-bypass valve, turn on the
sprayer pump, turn off agitation, and set the
engine to full throttle.
2.
To access the Flow screen, press button 4 on
the Calibrate screen (
) to select Flow.
3.
Fill the sprayer tank with a minimum of 700 L
(150 US gallons) of water and apply the parking
brake.
4.
Press button 2 to move to the next step and to
view the Select Nozzle Color screen.
5.
Use button 3 and button 4 to select the nozzle
that you are using.
6.
Press button 2 to move to the next step and to
view the To Proceed screen.
7.
Press button 2 to move to the next step and to
view the 15 Second Catch Test screen.
29