Fault Code Table (cont'd.)
Fault ID
Affected Component or
System
Description
Recommended Action
3
Main power relay fault
The main power relay is not
supplying current.
4
Charging system fault
Alternator voltage is too high or
too low.
14
Software version incompatibility
The software versions are
mismatched
17
Starter timeout
The starter was engaged too
long.
18
Taction pedal neutral switch
The traction pedal switch does
not match ground speed.
Call your Authorized Toro
Service Distributor.
19
Flow-rate meter
There is no signal from flow-rate
meter when spraying.
Spray in the manual mode; Call
your Authorized Toro Service
Distributor.
41
Sprayer pump-control valve
TEC controller electrical
problem.
Call your Authorized Toro
Service Distributor.
Maintenance
Service Screens
1.
To access the Service screen press button 2
on the Main Menu screen to navigate to the
SERVICE
option (
); refer to
the Main Menu Screen (page 3)
.
g192026
Figure 79
2.
Press button 4 to select
SERVICE
sub-menu
(
).
This screen displays and allows you to display
hours and flow rate information.
Viewing the Service Hours
1.
Press button 1 or 2 on the Service screen until
you reach the
HOURS
option (
g192029
Figure 80
2.
Press button 4 to select the Hours entry (
3.
Use the counter information (
)
displayed on the screen to determine the
following:
30