Removing and Installing the Battery (continued)
7. Clean the battery tray. Neutralize and refinish any damaged areas of the
battery tray.
8. Inspect the battery cables and connectors for damage and corrosion. Clean,
repair, or replace the battery cables and connectors if necessary.
9. Install the battery in the reverse order:
IMPORTANT
To prevent possible electrical problems, install only a fully
charged battery.
A. Connect the positive (+) cable connector onto the positive (+) battery
terminal.
B. Connect a digital multimeter (set to A) between the negative (-) battery
post and the negative (-) cable connector. Ensure that the reading is less
than 0.1 A. A reading of more than 0.1 A usually indicates a damaged
switch, a shorted circuit, or grounded wire. Identify and repair the
electrical faults before returning the machine to service.
C. Connect the negative (-) cable connector to the negative (-) battery
terminal. The cable clamp must be parallel to the edge of the battery
before securing the clamp.
10. After you make the connections, apply battery terminal protector Toro Part
No. 107-0392 or a light layer of petroleum jelly to the battery terminals and
cable connectors.
11. Make sure that the rubber boots are in place over the positive cable end at
the battery post and at the starter.
Inspecting, Maintaining, and Testing the Battery
Temperature Correcting Specific Gravity
Cell Temperature
100°F
Cell Specific Gravity
1.245
38°C minus 27°C equals 11.0°C
(100°F minus 80°F equals 20°F)
11°C multiply by 0.004/5.5°C equals 0.008
(20°F multiply by 0.004/10°F equals 0.008)
ADD (conversion above)
0.008
Correction to 27°C (80°F)
1.253
Minimum Voltage
Minimum Voltage
Battery-Electrolyte Temperature
9.6
70°F (and up)
21°C (and up)
9.5
60°F
15°C
9.4
50°F
10°C
9.3
40°F
4°C
9.1
30°F
-1°C
Groundsmaster
®
3200, 3300 and 3310
Page 6–65
Electrical System: Service and Repairs
19240SL Rev A
Содержание Groundmaster 31900
Страница 4: ...Reader Comments Page 4 Groundsmaster 3200 3300 and 3310 19240SL Rev A...
Страница 16: ...Safety Safety and Instructional Decals Page 1 8 Groundsmaster 3200 3300 and 3310 19240SL Rev A...
Страница 36: ...Specifications and Maintenance Special Tools Page 2 20 Groundsmaster 3200 3300 and 3310 19240SL Rev A...
Страница 86: ...Engine Service and Repairs Page 4 24 Groundsmaster 3200 3300 and 3310 19240SL Rev A...
Страница 316: ...General Information Operator Cab General Information Page 9 2 Groundsmaster 3200 3300 and 3310 19240SL Rev A...
Страница 332: ...Operator Cab Service and Repairs Page 9 18 Groundsmaster 3200 3300 and 3310 19240SL Rev A...
Страница 335: ...Model 31900 Drawing 133 6540 Rev A Sheet 1 of 1 19240SL Rev A Page A 3 Hydraulic Schematic 3200 2WD g296996...
Страница 336: ...Page A 4 19240SL Rev A Model 31901 Drawing 138 4500 Rev A Sheet 1 of 1 Hydraulic Schematic 3200 4WD g303916...
Страница 339: ...Model 31902 and 31903 Drawing 122 1220 Rev A Sheet 1 of 2 19240SL Rev A Page A 7 Electrical Schematic 3300 3310 g296989...
Страница 347: ...Model 31903 and 31909 Drawing 122 1435 Rev A Sheet 1 of 1 19240SL Rev A Page A 15 Wire Harness Cab Power g297520...
Страница 348: ...Page A 16 19240SL Rev A Model 31903 and 31909 Drawing 122 1245 Rev D Sheet 1 of 1 Wire Harness Cab Rooftop g256477...
Страница 349: ...Model 31903 and 31909 Drawing 122 1660 Rev A Sheet 1 of 1 19240SL Rev A Page A 17 Wire Harness Cab Control Panel g297533...
Страница 350: ...Page A 18 19240SL Rev A Model 31903 and 31909 Drawing 122 1678 Rev A Sheet 1 of 1 Wire harness Cab HVAC Adapter g297534...
Страница 351: ...Model 31993 Drawing 122 1248 Rev B Sheet 1 of 1 19240SL Rev A Page A 19 Wire Harness Cab Work Light Kit optional g260313...
Страница 355: ......