Servicing the Bedknife
g251263
Figure 161
eFlex 2100/2120 shown
1.
Screw (13 each)
3.
Bedknife
2.
Bedbar
Removing the Bedknife
1. Remove the bedbar from the cutting unit; refer to
(page 7–10)
.
Note:
EFlex 1800 cutting units use 11 screws to secure bedknife to bedbar.
EFlex 2100/2120 cutting units use 13 screws to secure bedknife to bedbar.
2. Remove the screws from the bedbar with a socket wrench and a bedknife
screw tool; refer to
Bedknife Screw Tool (page 2–17)
. Discard the screws.
Remove the bedknife from the bedbar.
3. Refer to
Grinding the Bedknife (page 7–14)
for additional information.
Installing the Bedknife
1.
Use a scraper to remove all rust, scale and corrosion from the bedbar
surface under the bedknife. Lightly oil the bedbar surface before installing
the bedknife.
2.
Make sure that screw threads in bedbar (5/16-18UNC-2A) are clean.
g226894
Figure 162
Greensmaster
®
eFlex 1800, 2100 and 2120
Page 7–13
Cutting Unit: Service and Repairs
12189SL Rev E