background image

Nozzle Performance Chart

 

FLX35 Series Performance Chart—25°

Front

Nozzle

Positions

Nozzle Set 30 

(White Plug)

Nozzle Set 31 

 

(Yellow)

Nozzle Set 32 

 

(Blue)

Nozzle Set 33 

(Brown)

Nozzle Set 34 

 

(Orange)

Nozzle Set 35 

(Green)

Nozzle Set 36 

 

(Gray)

Nozzle Set 37 

(Black)

102-2208

102-6906

102-0726

102-6907

102-0728

102-6955

102-6935

102-6936

Yellow

Biege

Yellow

Brown

Yellow

Yellow

Yellow

Yellow

Yellow

Yellow

Yellow

Green

Green

Green

Green

Green

102-5670 102-6942 102-5670 102-5671 102-5670 102-6884 102-5670 102-6884 102-5670 102-6884 102-5670 102-6885 102-6531 102-6885 102-6531 102-6885

Back

Nozzle

Positions

Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug

102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335

PSI

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

50

43

8.2

53

13.8

56

18.3

61

21.7

65

25.3

65

45

10.0

53

15.5

59

20.5

64

24.4

68

28.2

72

34.1

80

46

11.5

57

17.3

62

22.7

67

27.1

71

31.1

75

37.8

78

40.3

80

44.0

100

47

13.4

59

19.1

65

24.9

70

29.8

74

34.1

79

40.9

81

43.8

83

47.3

FLX35 Series Performance Chart—15°

Stator

102-6929 Blue

102-1939 Yellow

102-1940 White

Conversions

FLX35-3134

FLX35-3537

 Not recommended at these pressures. Radius shown in feet. 

Toro recommends the use of a 1

1

4

" swing joint at flows over 25-GPM (95-LPM). Sprinkler radius data collected in Toro’s zero wind test facility per ASAE standard S398.1.

Actual site conditions must be considered when selecting the appropriate nozzle.

All sprinklers are equipped with the selectable pilot valve that allows settings at 50, 65, 80 and 100 PSI.

PSI

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

50

43

8.2

52

13.6

58

18.1

61

21.5

62

25.6

65

45

10.0

54

15.3

60

20.3

64

24.2

65

27.3

69

33.1

80

46

11.5

58

17.2

64

22.6

69

26.8

69

30.2

75

36.8

76

39.7

76

42.9

100

47

13.4

60

19.0

66

24.7

71

29.5

72

32.9

78

39.5

82

42.6

82

46.1

FLX55 Series Performance Chart—25°

Front

Nozzle

Positions

Nozzle Set 51 

(Yellow)

Nozzle Set 52 

 

(Blue)

Nozzle Set 53 

 

(Brown)

Nozzle Set 54 

 

(Orange)

Nozzle Set 55 

 

(Green)

Nozzle Set 56 

 

(Gray)

Nozzle Set 57 

 

(Black)

Nozzle Set 58 

(Red)

Nozzle Set 59 

 

(Beige)

102-6906

102-0726

102-6907

102-0728

102-6955

102-6935

102-6936

102-6909

102-4259

Yellow

Brown

Yellow

Yellow

Yellow

Yellow

Yellow

Yellow

Yellow

Green

Green

Green

Green

Green

Green

Green

Green

Green

102-5670 102-5671 102-5670 102-6884 102-5670 102-6884 102-5670 102-6884 102-5670 102-6885 102-6531 102-6885 102-6531 102-6885 102-6531 102-6885 102-6531 102-6885

Back

Nozzle

Positions

Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug Red Plug

102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335 102-4335

PSI

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

50

55

14.1

57

18.5

62

22.3

66

25.8

65

57

15.8

60

20.9

65

25.1

69

28.7

73

35.9

80

59

17.5

61

23.1

68

27.8

72

31.7

76

39.7

80

43.1

83

48.2

85

50.0

89

57.5

100

61

19.3

63

25.3

71

30.3

75

34.5

80

43.5

83

49.0

88

51.5

90

53.9

92

61.3

FLX55 Series Performance Chart—15°

Stator

102-1939 Yellow

102-1940 White

Conver-

sions

FLX55-5154

FLX55-5558

 Not recommended at these pressures. Radius shown in feet. 

Toro recommends the use of a 1

1

4

" swing joint at flows over 25-GPM (95-LPM). Sprinkler radius data collected in Toro’s zero wind test facility per ASAE standard S398.1.

Actual site conditions must be considered when selecting the appropriate nozzle.

All sprinklers are equipped with the selectable pilot valve that allows settings at 50, 65, 80 and 100 PSI.

PSI

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

Radius

GPM

50

55

14.0

59

16.5

62

22.2

63

25.6

65

56

15.6

62

20.7

65

25.0

66

28.5

75

35.3

80

59

17.4

66

23.0

69

27.7

70

31.5

78

39.0

78

42.4

79

46.9

79

49.5

82

57.2

100

60

19.2

68

25.1

71

30.2

72

34.3

80

41.9

81

47.2

83

52.1

83

53.4

85

60.8

FLX55-59

102-1941 White

Содержание FLX35 Series

Страница 1: ...Series Radius 43 83 13 1 25 3 m Flow Rate 8 2 47 3 GPM 31 179 LPM Trajectory Selectable 15 or 25 Arc Full Circle 360 or adjustable part circle 40 330 Recommended Operating Pressure 65 100 PSI 4 5 6 9...

Страница 2: ...9 0 66 24 7 71 29 5 72 32 9 78 39 5 82 42 6 82 46 1 FLX55 Series Performance Chart 25 Front Nozzle Positions Nozzle Set 51 Yellow Nozzle Set 52 Blue Nozzle Set 53 Brown Nozzle Set 54 Orange Nozzle Set...

Страница 3: ...pipe thread connections Use of pipe dope or other paste sealants can cause deterioration of the sprinkler body threads Tape should be applied to the male threaded fitting in compliance with the tape m...

Страница 4: ...tomatic operation or when performing sprinkler service procedures Direct contact with irrigation spray a failed or improperly installed sprinkler connection or sprinkler components forcibly ejected up...

Страница 5: ...the right side of the arc located at the end of the clockwise rotation Step 1 Using the sprinkler tool pull the sprinkler riser up from the body See Figure 2 Step 2 Find the sprinkler left stop by ro...

Страница 6: ...N 995 99 to turn the main nozzle assembly Turn the main nozzle assembly clockwise until the angle indicator points towards the right to set 25 trajection Continue turning the main nozzle clockwise unt...

Страница 7: ...auses and corrective action are listed below Sprinkler won t rotate Debris wedged between stator and turbine Remove obstruction Drive assembly defective Replace drive assembly Nozzle base assembly def...

Страница 8: ...lve seat Remove blockage and if necessary replace valve assembly Damaged piston seal or piston assembly Replace valve assembly Damaged pilot valve discharge seat Clean or replace pilot valve Damaged p...

Страница 9: ...ly turn the screen counterclockwise to remove Step 4 Remove the variable stator 16 from riser assembly Step 5 Remove the drive assembly retaining screw 14 and pull the drive assembly 15 using a pair o...

Страница 10: ...al tool is not available use snap ring pliers to grasp rib of valve cylinder assembly and pull up and out of sprinkler body Step 3 Reinstall valve assembly using valve insertion tool P N 995 76 for FL...

Страница 11: ...Step 7 Remove the retaining nut 18 and washer 17 from the pressure adjuster 11 and pull the pilot valve body assembly out of housing 16 Step 8 Remove diaphragm assembly 15 piston 14 spring 13 traveli...

Страница 12: ...NOTES 2015 The Toro Company Irrigation Division www toro com Form Number 373 0859 Rev A...

Отзывы: