Thank you for choosing the Toro DDCWP Waterproof Battery

Controller. The DDCWP incorporates the latest programming
technology in an easy-to-use, "digital dial" display. 

The following instructions will help you get started. As you

follow the simple steps, please pay attention to the important
NOTES, which will give you helpful hints and programming
advice to maximize the feature capability of the DDCWP.

Controller Specifications . . . . . . . . . . . . . . . . . . . . . . . . 
Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . 
Sensor Connection and Operation. . . . . . . . . . . . . . . . . 
Programming. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

- SET TIME/DAY . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
- RUN TIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
- WATER DAYS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
- START TIMES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
- SEASON ADJUST. . . . . . . . . . . . . . . . . . . . . . . . . . .
- MANUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
- MANUAL PROGRAMS. . . . . . . . . . . . . . . . . . . . . . . 
- SYSTEM OFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
- AUTO-RUN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Programming Lock Out Feature. . . . . . . . . . . . . . . . . . .  

About the DDCWP Memory. . . . . . . . . . . . . . . . . . . . . 
Wire Run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Custom Watering Plan . . . . . . . . . . . . . . . . . . . . . . . . . 

Page 3

Page 3-4

Page 5
Page 6
Page 6
Page 6
Page 7
Page 7
Page 8
Page 8
Page 9
Page 9

Page 10
Page 11

Page 11
Page 11
Page 12

Automatic Voltage Detection

The DDCWP has an automatic voltage detection circuit. Before an 

irrigation start is initiated, this circuit checks battery voltage to insure that

there is sufficient voltage remaining to shut the solenoids off. If there is not

sufficient voltage, the program is cancelled and the low battery icon is

turned on in the LCD display. 

About the DDCWP memory

This controller is equipped with "on board" back up battery that will keep

the program memory for a few months in case power is not available. The 9

volt battery will turn on both displays and programming is possible.  Do not 

remove batteries for winter months as program loss can occur.

Maximum Wire Runs for DDCWP Controller

With battery voltage at 9V DC and 7 Bars (105 PSI) of pressure at the

valve, these are the maximum wire runs for an 8 station DDCWP.

AWG # 18 (1.0mm

2

) multi-strand wire – 60m (197')

AWG # 16 (1.5mm

2

) multi-strand wire – 100m (305')

AWG # 14 (2.5mm

2

) multi-strand wire – 150m (493')

AWG # 12 (4.0mm

2

) multi-strand wire – 250m (820')

- 2 -

- 11 -

TABLE OF CONTENTS

ddcwp_manual_gb_revised.ai  10/23/06   Page 2

Programming Lock Out Feature

The DDCWP can be locked so that unauthorized programming can not 

occur. In the AUTO RUN position, press both +/ON and -/OFF buttons and 

hold for 5 seconds. The DDCWP will be "locked" in the AUTO RUN posi-

tion.  Repeat this sequence to "unlock" the DIAL button.

The Toro Promise — Limited Two-Year Warranty

The Toro Company and its affiliate, Toro Warranty Company, pursuant to an agreementbetween them, 

jointly warrants, to the owner, each new piece of equipment (featured in the current catalog at date of 

installation) against defects in material and workmanshipfor a period described below, provided they are 

used for irrigation purposes under manufacturer's recommended specifications. Product failures due to acts 

of God (i.e., lightning, flooding, etc.) are not covered by this warranty. Neither Toro nor Toro Warranty 

Company is liable for failure of products not manufactured by them even though such products may be sold 

or used in conjunction with Toro products. During such warranty period, we will repair or replace, at our 

option, any part found to be defective. Your remedy is limited solely to the replacement or repair of defective 

parts. Return the defective part to your local Toro distributor, who may be listed in your telephone directory 

Yellow Pages under "Irrigation Supplies" or "Sprinkler Systems," or contact The Toro Warranty Company P.O. 

Box 489, Riverside, California, 92502. Phone (800) 664-4740 for the location of your nearest Toro distributor 

or outside the U.S., call (951) 688-9221. This warranty does not apply where equipment is used, or 

installation is performed, in any manner contrary to Toro’s specifications and instructions, nor where 

equipment is altered or modified. Neither Toro nor Toro Warranty Company is liable for indirect, incidental 

or consequential damages in connection with the use of equipment, including but not limited to: vegetation 

loss, the cost of substitute equipment or services required during periods of malfunction or resulting non-use, 

property damage or personal injury resulting from installer’s actions, whether negligent or otherwise. Some 

states do not allow the exclusion or limitation of incidental or consequential damages, so the above 

limitation or exclusion may not apply to you. All implied warranties, including those of merchantability and 

fitness for use, are limited to the duration of this express warranty. Some states do not allow limitations of 

how long an implied warranty lasts, so the above limitation may not apply toyou. This warranty gives you 

specific legal rights and you may have other rights which vary from state to state. The DDCWP controller is 

covered by this warranty for a period of two years from the date of installation.