background image

7

Service Procedures  ______________________________________________________________

Servicing Sprinkler Mechanism

Note:

Refer to 

Figure 13

for the following procedure.

1. Remove the cap screw (1) and cap (2).

Note:

During reassembly, ensure the cap is correctly installed with the Toro Logo positioned over the main nozzle (10).

2. Insert the hooked end of the multi-purpose tool (P/N 995-83) into the snap ring slot (3). Pull the snap ring inward towards the

sprinkler assembly, then upward to remove from the groove in body.

Note:

During reassembly, ensure the snap ring is correctly installed and fully seated in the sprinkler body.

3. Insert the hooked end of the tool into the slot provided in the nozzle base above the right intermediate nozzle (9). Pull the riser

assembly until enough clearance to handle. Hold onto the riser body (13) and carefully extract it from the sprinkler body. 

CAUTION: The seal/retainer (4) will eject (caused by the decompressing spring [5]) as it clears the sprinkler body.

4. Three small tabs are provided on the edge of the multi-purpose tool. Insert tabs into the debris filter screen (17). Holding the

plastic base of riser assembly, turn the screen counterclockwise to remove.

5. Remove the variable stator (16) from riser assembly.

6. Loosen the drive assembly retaining screw (14) 6–7 turns and pull the drive assembly (15) using a pair of pliers. See 

Figure 14

Note:

Do not remove the retaining screw completely as it is easily misplaced.

CAUTION: When removing or installing the drive assembly, do not use the turbine to pull the drive assembly. Use the

drive assembly body to extract it out. Failure to comply may cause separation of the drive assembly components.

Note:

During reassembly, ensure drive assembly is properly aligned with the retaining screw.

7. Using a 5/8" nut driver (P/N 995-99), unscrew main nozzle (10) from nozzle base assembly.

8. Using a 5/16" nut driver (P/N 995-105), unscrew the inner (8) and intermediate (9) nozzles.

9. Thoroughly clean and inspect all parts and replace as necessary. Reassemble in reverse order.

10. When installing the riser assembly to the sprinkler body, align the ratchet ring with the inside body rib. Use the indicator on top of

the sprinkler body to center the ratchet ring. See 

Figure 15

2

13

15

16

17

1

3

4

5

6

12

14

8

10

11

9

7

Figure 13

Figure 14

WARNING

NEVER STAND OR LEAN OVER THE SPRINKLER WHILE THE IRRIGATION SYSTEM IS BEING FILLED, DURING
MANUAL OR AUTOMATIC OPERATION OR WHEN PERFORMING SPRINKLER SERVICE PROCEDURES. DIRECT
CONTACT WITH IRRIGATION SPRAY, A FAILED OR IMPROPERLY INSTALLED SPRINKLER CONNECTION OR
SPRINKLER COMPONENTS FORCIBLY EJECTED UPWARD UNDER PRESSURE CAN CAUSE SERIOUS INJURY.

Figure 15

Содержание 835S Series

Страница 1: ...wire legs See example in Figure 2 2 Attach control wires to solenoid leads using an approved waterproof splicing method CAUTION All wire splices and field connections must be waterproofed to prevent s...

Страница 2: ...relieve it bleed the air continuously while filling the system 3 After water has filled all lines and all air is removed remove the quick coupler keys Table 3 Recommended System Fill Rate Table 2 Hydr...

Страница 3: ...t area See Figure 5 CAUTION The riser can only ratchet when the sprinkler is not operating Attempting to ratchet the riser during operation may damage the sprinkler The turret can also be used to adju...

Страница 4: ...re equipped with the Trujectory TM nozzle spray angle adjustment feature The trajectory adjusts from the top of the sprinkler enabling fine tuning from 7 30 to compensate for windy conditions spraying...

Страница 5: ...et to AUTO position c Debris in pilot valve assembly Disassemble and remove all debris See Servicing Pilot Valve page 12 d Insufficient pressure in controller supply line and or sprinkler control tube...

Страница 6: ...from controller to solenoid Check for blown fuse and replace d Manual control selector on pilot valve assembly turned to OFF position Turn to AUTO position e Pilot valve solenoid inoperative Remove a...

Страница 7: ...r assembly 6 Loosen the drive assembly retaining screw 14 6 7 turns and pull the drive assembly 15 using a pair of pliers See Figure 14 Note Do not remove the retaining screw completely as it is easil...

Страница 8: ...n carrier as shown Locate position of communication tube in bottom of sprinkler body and orient insertion tool accordingly Insert tool straight down into sprinkler body aligning bosses on t handle wit...

Страница 9: ...necessary and reassemble in reverse order Note Refer to Illustrated Parts Breakout Book form number 490 3043 for service part numbers Flushing Sprinkler _______________________________________________...

Отзывы: